PatchSiren

Rockwell Automation CVE debriefs · Page 2

These pages are published after PatchSiren validates generated defensive summaries against stored public CVE and source evidence.

HIGH Rockwell Automation CVE published 2026-07-14

CVE-2026-11917

A path traversal security issue exists within Rockwell Automation ThinManager software due to improper limitation of file save operations within the API. An authenticated attacker could exploit this vulnerability to write arbitrary files to restricted system directories outside of the application's intended directory. This could lead to elevated privileges or unauthorized data modifications. ThinManager administrators and users should assess exposure and prioritize upgrading to patched versions to prevent potential arbitrary file writes.

CRITICAL Rockwell Automation CVE published 2026-07-14

CVE-2026-10577

AI-assisted PatchSiren debrief based on the supplied source corpus. The CVE record was published on 2026-07-14T06:00:00.000Z and has not been modified since then. The Rockwell Automation 1715-AENTR EtherNet/IP Adapter is affected by a critical vulnerability that allows unauthenticated remote access to intrusive command-line interface (CLI) commands via a network-accessible debug port without proper privilege controls. If exploited, a threat actor could read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device. To address this vulnerability, it is crucial to update to version 3.011 or later and implement network access controls and monitoring. The evidence limits of this advisory suggest that further investigation may be required to fully understand the impact of this vulnerability, and defenders should review the official advisory to validate affected scope, severity, and vendor guidance.

HIGH Rockwell Automation CVE published 2026-06-18

CVE-2025-13036

CVE-2025-13036 is a critical authentication bypass vulnerability in FactoryTalk Historian Site Edition. An attacker can exploit this vulnerability by continually sending requests to the login endpoint, potentially obtaining a valid authentication token. The vulnerability has a CVSS score of 9.2 and is considered critical.

MEDIUM Rockwell Automation CVE published 2026-06-16

CVE-2026-9307

A sensitive information disclosure security issue exists within the affected CompactLogix controllers. The controller's web server exposes CIP Connection IDs on the diagnostics webpage, which are accessible to any unauthenticated user on the network. This information can be leveraged by an attacker to construct malicious packets, leading to Denial-of-Service.

HIGH Rockwell Automation CVE published 2026-06-16

CVE-2026-11317

A denial of service security issue exists in the affected product. The security issue stems from a fault occurring when a crafted CIP message is sent. Devices with less memory are more likely to be affected. This can result in a major nonrecoverable fault (MNRF). A program download is required to recover.

CRITICAL Rockwell Automation CVE published 2026-06-16

CVE-2026-0647

CVE-2026-0647 is an improper authentication security issue within the 1794-AENTR adapter's embedded web server. The vulnerability allows an unauthenticated attacker to change the device's web interface password by sending a crafted HTTP GET request to a specific endpoint, without any prior authentication being required. If exploited, this could lead to unauthorized access, account takeover, and loss of the device’s embedded web server’s availability.

HIGH Rockwell Automation CVE published 2026-06-16

CVE-2026-0646

CVE-2026-0646 is a HIGH-severity denial-of-service vulnerability in the 1794-AENTR adapter. The issue arises from improper memory handling of CIP protocol requests, which can cause the adapter to fault and lose connection to its associated I/O modules. A manual reset is required to recover from this vulnerability. The Common Vulnerability Scoring System (CVSS) score for this vulnerability is 8.7.

HIGH Rockwell Automation CVE published 2026-06-16

CVE-2025-14272

CVE-2025-14272 is a HIGH-severity vulnerability (CVSS Score: 8.3) affecting an unknown vendor's product, potentially allowing unauthorized actors to execute privileged operations. The issue was published on 2026-06-16T15:16:33.000Z and last modified on 2026-06-16T15:26:04.250Z.

HIGH Rockwell Automation CVE published 2026-06-16

CVE-2025-11694

CVE-2025-11694 is a HIGH severity vulnerability with a CVSS score of 8.7. The vulnerability exists within 1769 CompactLogix controllers due to the missing validation of sequence numbers and source IP addresses in the CIP protocol. This allows an attacker to abuse the exposed Connection ID's visible on the web interface to perform denial-of-service attacks, resulting in a minor fault.

HIGH Rockwell Automation CVE published 2026-02-18

CVE-2020-11656

This debrief provides an analysis of CVE-2020-11656, a critical vulnerability in SQLite through version 3.31.1. The vulnerability is caused by a use-after-free in the ALTER TABLE implementation, which can be triggered by an ORDER BY clause in a compound SELECT statement. The vulnerability has a CVSS score of 9.8 and is considered critical. Defenders responsible for systems that use SQLite, especially in critical infrastructure or applications that rely on SQLite for data storage, should prioritize patching or mitigating this vulnerability. The vulnerability can lead to potential code execution, data corruption, or system instability. It is essential to review the supplied official

HIGH Rockwell Automation CVE published 2026-01-29

CVE-2025-9466

CVE-2025-9466 affects Rockwell Automation ArmorStart LT and can cause a denial-of-service condition. According to the CISA CSAF advisory published on 2026-01-29, execution of Achilles EtherNet/IP and CIP grammar tests may trigger an unexpected device reboot, taking the Link State Monitor down for several seconds. Rockwell Automation reported no patch or upgrade available at publication and recommended applying security best practices as a mitigation.

HIGH Rockwell Automation CVE published 2026-01-29

CVE-2025-9465

CVE-2025-9465 is a high-severity availability issue affecting Rockwell Automation ArmorStart LT products. CISA’s republication of Rockwell Automation advisory SD1768 states that, during execution of Achilles Comprehensive grammar tests, the device can reboot unexpectedly and cause the Link State Monitor to go down for several seconds. Rockwell’s guidance at the time was mitigation-focused: there was no patch or upgrade available, and users were advised to apply security best practices.

HIGH Rockwell Automation CVE published 2026-01-29

CVE-2025-9464

CVE-2025-9464 is a denial-of-service issue affecting Rockwell Automation ArmorStart LT. According to the CISA advisory, fuzzing multiple CIP classes can make the CIP port unresponsive. The advisory was published on 2026-01-29 and states that no patch or upgrade was available at that time; Rockwell advised applying security best practices to reduce risk.

HIGH Rockwell Automation CVE published 2026-01-29

CVE-2025-9283

CVE-2025-9283 describes an availability issue in Rockwell Automation ArmorStart LT. Per the CISA-republished advisory, the device can reboot unexpectedly during Achilles EtherNet/IP Step Limits Storms tests, which causes the Link State Monitor to go down for several seconds. The advisory states that no patch or upgrade is available at the time of publication, and recommends applying security best practices to reduce risk.

HIGH Rockwell Automation CVE published 2026-01-29

CVE-2025-9282

CVE-2025-9282 affects Rockwell Automation ArmorStart LT devices and is described as a denial-of-service issue. In the CISA republished advisory, the device can reboot unexpectedly during Achilles Comprehensive limited storm tests, causing the Link State Monitor to go down for several seconds. Rockwell Automation reported no patch or upgrade at the time of the advisory and recommended applying ICS security best practices as mitigation.

HIGH Rockwell Automation CVE published 2026-01-29

CVE-2025-9281

CVE-2025-9281 is a denial-of-service issue in Rockwell Automation ArmorStart LT. CISA’s 2026-01-29 advisory says the device can reboot unexpectedly during Achilles Comprehensive step limit storm tests, which causes the Link State Monitor to go down for several seconds. The advisory lists ArmorStart LT 290D, 291D, and 294D as affected and states that no patch or upgrade was available at publication, so operators should rely on Rockwell and CISA defensive guidance.

HIGH Rockwell Automation CVE published 2026-01-29

CVE-2025-9280

CVE-2025-9280 describes a denial-of-service condition in Rockwell Automation ArmorStart LT. According to the advisory summary, fuzzing with Defensics can make the device unresponsive and require a reboot. Rockwell states that no patch or upgrade is available at this time and recommends compensating security best practices.

HIGH Rockwell Automation CVE published 2026-01-29

CVE-2025-9279

CVE-2025-9279 is a denial-of-service issue affecting Rockwell Automation ArmorStart LT products. In the CISA-republished advisory, the device can reboot unexpectedly during Achilles EtherNet/IP Step Limit Storm testing, which drops the Link State Monitor for several seconds. CISA’s source material lists no patch or upgrade at the time of publication and recommends applying security best practices as a mitigation.

HIGH Rockwell Automation CVE published 2026-01-29

CVE-2025-9278

CVE-2025-9278 is a denial-of-service issue in Rockwell Automation ArmorStart LT. According to the advisory text, running a Burp Suite active scan can cause the device to lose ICMP connectivity, which then makes the web application inaccessible. CISA republished the vendor advisory on 2026-01-29 as ICSA-26-029-02.

HIGH Rockwell Automation CVE published 2026-01-29

CVE-2025-14027

CVE-2025-14027 covers multiple denial-of-service weaknesses in Rockwell Automation ControlLogix Redundancy Enhanced Modules 1756-RM2 and 1756-RM2XT firmware. According to the CISA CSAF advisory, crafted inputs such as malformed Class 3 messages, memory leak conditions, and other resource-exhaustion scenarios can cause the device to become unresponsive and, in some cases, trigger a major nonrecoverable fault. Recovery may require a restart. Rockwell’s stated mitigation is to upgrade from 1756-RM2 to 1756-RM3; if that is not possible, apply security best practices and defense-in-depth controls.

MEDIUM Rockwell Automation CVE published 2026-01-22

CVE-2025-11743

Rockwell Automation CompactLogix 5370 has a denial-of-service vulnerability that can be triggered by a malformed CIP forward open message. According to the CISA advisory, the condition can cause a major nonrecoverable fault and require a restart to recover. Rockwell provides fixed versions for affected branches, and CISA also points readers to Rockwell security guidance for systems that cannot be upgraded immediately.

HIGH Rockwell Automation CVE published 2026-01-20

CVE-2025-14377

CVE-2025-14377 is a high-severity information exposure issue in Rockwell Automation Verve Asset Manager’s legacy Ansible playbook component. According to the CISA republication of the vendor advisory, sensitive information could be incorrectly stored in unencrypted form during playbook execution. Rockwell Automation states the issue was resolved in version 1.42, and that the legacy component became optional starting with version 1.36 in 2024.

HIGH Rockwell Automation CVE published 2026-01-20

CVE-2025-14376

CVE-2025-14376 was publicly disclosed on 2026-01-20 in CISA's republished advisory for Rockwell Automation Verve Asset Manager. The issue affects the legacy ADI server component, where unencrypted sensitive data was stored in environment variables. Rockwell Automation states the issue was resolved in version 1.42, and that the component became optional beginning with version 1.36 in 2024, which means exposure is most relevant to deployments that still use that legacy path.

HIGH Rockwell Automation CVE published 2026-01-13

CVE-2025-9368

Rockwell Automation’s 432ES-IG3 Series A is affected by a denial-of-service vulnerability in the GuardLink EtherNet/IP Interface. According to the CISA-republished advisory, the condition can disrupt availability and requires a manual power cycle to restore the device. Rockwell’s documented fix is to update to V2.001.9 or later.

HIGH Rockwell Automation CVE published 2026-01-13

CVE-2025-12807

CVE-2025-12807 is a high-severity issue in Rockwell Automation FactoryTalk DataMosaix Private Cloud. CISA’s advisory says low-privilege users can perform sensitive database operations through exposed API endpoints. The supplied CVSS 3.1 vector (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) scores 8.8, so this should be treated as a serious exposure in environments running the affected product. The advisory’s revision history also labels the initial publication as a “FactoryTalk DataMosaix Private Cloud SQL Injection” issue, but the core defensive takeaway is the same: limit API exposure, assume low-privilege access paths may be abused, and apply the vendor correction promptly. Rockwell Automation’s stated fix is Version 8.01.02 or later.

HIGH Rockwell Automation CVE published 2025-12-18

CVE-2025-13824

A vulnerability in Rockwell Automation Micro800 series programmable logic controllers (PLCs) allows remote attackers to cause a denial-of-service condition by sending malformed Common Industrial Protocol (CIP) packets to affected devices. The vulnerability was identified during fuzzing activities and results in the controller entering a hard fault state with a solid red Fault LED, rendering the device unresponsive until power-cycled. After power cycling, the controller enters a recoverable fault state. The CVSS 3.1 score of 7.5 reflects network-based attackability with low complexity and no required privileges or user interaction, resulting in high availability impact. The vulnerability affects Micro820 controllers running firmware V14.011 and prior, as well as Micro850 and Micro870 controllers. Rockwell Automation has issued corrective updates and security best practice guidance for affected deployments.

MEDIUM Rockwell Automation CVE published 2025-12-18

CVE-2025-13823

A recoverable fault condition exists in the IPv6 stack of Rockwell Automation Micro850 and Micro870 programmable logic controllers. The vulnerability triggers when affected controllers receive multiple malformed IPv6 packets, as discovered during fuzzing activities. The fault is recoverable, indicating the controller can resume normal operation without permanent damage, but successful exploitation results in a high availability impact. The attack vector requires adjacent network access, with low attack complexity and no required privileges or user interaction.

HIGH Rockwell Automation CVE published 2025-11-13

CVE-2024-22019

Rockwell Automation FactoryTalk Policy Manager is affected by CVE-2024-22019, a network-reachable denial-of-service issue in Node.js HTTP server handling of chunked encoding. According to the CISA CSAF advisory, a specially crafted HTTP request can cause the server to read an unbounded number of bytes from a single connection via chunk extension processing, which can exhaust CPU and network bandwidth and bypass common safeguards such as timeouts and body-size limits. Rockwell Automation states the issue is corrected in software Version 6.60.00 and later. The supplied corpus does not indicate KEV listing, known ransomware use, or exploit details beyond the advisory description, so the main defensive focus should be prompt patching and limiting exposure of the affected service.

HIGH Rockwell Automation CVE published 2025-10-14

CVE-2025-9177

CVE-2025-9177 is a denial-of-service issue in Rockwell Automation’s 1715 EtherNet/IP Comms Module. According to the CISA CSAF advisory, a high volume of requests can crash the module’s web server. The advisory states that I/O control and communication are not impacted, but the webpage is unavailable until the device is power-cycled.

CRITICAL Rockwell Automation CVE published 2025-07-31

CVE-2025-41236

CVE-2025-41236 is a critical integer-overflow vulnerability in VMware’s VMXNET3 virtual network adapter. CISA’s Rockwell Automation advisory maps the issue to multiple Rockwell Automation VMware-based product families and directs customers to Broadcom’s remediation guidance. The stated impact is code execution on the host.