CVE-2025-9279 is a denial-of-service issue affecting Rockwell Automation ArmorStart LT products. In the CISA-republished advisory, the device can reboot unexpectedly during Achilles EtherNet/IP Step Limit Storm testing, which drops the Link State Monitor for several seconds. CISA’s source material lists no patch or upgrade at the time of publication and recommends applying security best practices as a mitigation.
CVE-2025-9278 is a denial-of-service issue in Rockwell Automation ArmorStart LT. According to the advisory text, running a Burp Suite active scan can cause the device to lose ICMP connectivity, which then makes the web application inaccessible. CISA republished the vendor advisory on 2026-01-29 as ICSA-26-029-02.
CVE-2025-14027 covers multiple denial-of-service weaknesses in Rockwell Automation ControlLogix Redundancy Enhanced Modules 1756-RM2 and 1756-RM2XT firmware. According to the CISA CSAF advisory, crafted inputs such as malformed Class 3 messages, memory leak conditions, and other resource-exhaustion scenarios can cause the device to become unresponsive and, in some cases, trigger a major nonrecoverable fau [truncated]
Rockwell Automation CompactLogix 5370 has a denial-of-service vulnerability that can be triggered by a malformed CIP forward open message. According to the CISA advisory, the condition can cause a major nonrecoverable fault and require a restart to recover. Rockwell provides fixed versions for affected branches, and CISA also points readers to Rockwell security guidance for systems that cannot be upgraded [truncated]
CVE-2025-14377 is a high-severity information exposure issue in Rockwell Automation Verve Asset Manager’s legacy Ansible playbook component. According to the CISA republication of the vendor advisory, sensitive information could be incorrectly stored in unencrypted form during playbook execution. Rockwell Automation states the issue was resolved in version 1.42, and that the legacy component became option [truncated]
CVE-2025-14376 was publicly disclosed on 2026-01-20 in CISA's republished advisory for Rockwell Automation Verve Asset Manager. The issue affects the legacy ADI server component, where unencrypted sensitive data was stored in environment variables. Rockwell Automation states the issue was resolved in version 1.42, and that the component became optional beginning with version 1.36 in 2024, which means expo [truncated]
Rockwell Automation’s 432ES-IG3 Series A is affected by a denial-of-service vulnerability in the GuardLink EtherNet/IP Interface. According to the CISA-republished advisory, the condition can disrupt availability and requires a manual power cycle to restore the device. Rockwell’s documented fix is to update to V2.001.9 or later.
CVE-2025-12807 is a high-severity issue in Rockwell Automation FactoryTalk DataMosaix Private Cloud. CISA’s advisory says low-privilege users can perform sensitive database operations through exposed API endpoints. The supplied CVSS 3.1 vector (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) scores 8.8, so this should be treated as a serious exposure in environments running the affected product. The advisory’s revis [truncated]
A vulnerability in Rockwell Automation Micro800 series programmable logic controllers (PLCs) allows remote attackers to cause a denial-of-service condition by sending malformed Common Industrial Protocol (CIP) packets to affected devices. The vulnerability was identified during fuzzing activities and results in the controller entering a hard fault state with a solid red Fault LED, rendering the device unr [truncated]
A recoverable fault condition exists in the IPv6 stack of Rockwell Automation Micro850 and Micro870 programmable logic controllers. The vulnerability triggers when affected controllers receive multiple malformed IPv6 packets, as discovered during fuzzing activities. The fault is recoverable, indicating the controller can resume normal operation without permanent damage, but successful exploitation results [truncated]
Rockwell Automation FactoryTalk Policy Manager is affected by CVE-2024-22019, a network-reachable denial-of-service issue in Node.js HTTP server handling of chunked encoding. According to the CISA CSAF advisory, a specially crafted HTTP request can cause the server to read an unbounded number of bytes from a single connection via chunk extension processing, which can exhaust CPU and network bandwidth and [truncated]
CVE-2025-9177 is a denial-of-service issue in Rockwell Automation’s 1715 EtherNet/IP Comms Module. According to the CISA CSAF advisory, a high volume of requests can crash the module’s web server. The advisory states that I/O control and communication are not impacted, but the webpage is unavailable until the device is power-cycled.
CVE-2025-41236 is a critical integer-overflow vulnerability in VMware’s VMXNET3 virtual network adapter. CISA’s Rockwell Automation advisory maps the issue to multiple Rockwell Automation VMware-based product families and directs customers to Broadcom’s remediation guidance. The stated impact is code execution on the host.
CVE-2018-1285 is a critical XXE issue mapped by CISA to Rockwell Automation FactoryTalk Historian ThingWorx product 95057C-FTHTWXCT11. The advisory states that Apache log4net versions before 2.0.10 do not disable XML external entities when parsing configuration files, which can expose applications that accept attacker-controlled log4net configuration files to high-impact data exposure and manipulation risks.
CVE-2025-3618 is a high-severity denial-of-service vulnerability in Rockwell Automation ThinManager. According to CISA’s advisory, the software does not adequately verify the outcome of memory allocation while processing Type 18 messages, which can let an attacker cause a denial of service on the target software. Rockwell Automation states the issue is fixed in multiple ThinManager releases, including 11. [truncated]
CVE-2025-3289 is a high-severity local code execution vulnerability in Rockwell Automation Arena. According to CISA’s advisory, improper validation of user-supplied data can trigger a stack-based memory buffer overflow. If a legitimate user opens a malicious DOE file, an attacker could disclose information and execute arbitrary code on the system. CISA published the advisory on 2025-04-10 and later revise [truncated]
CVE-2025-3288 is a high-severity local code execution vulnerability in Rockwell Automation Arena. CISA’s advisory says the flaw stems from improper validation of user-supplied data, which can lead to reading outside the allocated memory buffer. If a legitimate user opens a malicious DOE file on an affected system, an attacker may be able to disclose information and execute arbitrary code.
CVE-2025-3287 is a high-severity local code execution vulnerability in Rockwell Automation Arena. According to the CISA advisory, a legitimate user must open a malicious DOE file, and improper validation of user-supplied data can lead to reading outside the allocated memory buffer. The reported impact includes information disclosure and arbitrary code execution on the system. Rockwell Automation advises u [truncated]
CVE-2025-3286 is a high-severity local code execution issue in Rockwell Automation Arena. CISA’s advisory says the flaw stems from improper validation of user-supplied data and an out-of-bounds memory read, and that exploitation can disclose information and execute arbitrary code if a legitimate user opens a malicious DOE file. Rockwell Automation’s mitigation is to upgrade to V16.20.09 or later.
CVE-2025-3285 affects Rockwell Automation Arena and is rated CVSS 7.8 (High). CISA’s advisory describes a local code execution flaw caused by improper validation of user-supplied data, allowing a read outside the allocated memory buffer. In practical terms, a legitimate user must open a malicious DOE file for the issue to be triggered, and successful exploitation could disclose information and execute arb [truncated]
CVE-2025-2829 is a high-severity flaw in Rockwell Automation Arena that can let an attacker disclose information and execute arbitrary code on a system. According to CISA’s advisory, the issue affects Arena version 16.20.08 and earlier, and exploitation requires a legitimate user to open a malicious DOE file. Rockwell Automation recommends upgrading to V16.20.09 or later.
CVE-2025-2293 is a high-severity local code execution vulnerability in Rockwell Automation Arena. According to the CISA CSAF advisory, a legitimate user opening a malicious DOE file can trigger a write outside the allocated memory buffer, which may allow information disclosure and arbitrary code execution. Rockwell Automation states that Arena versions up to 16.20.08 are affected and recommends upgrading [truncated]
CVE-2025-2288 is a high-severity local code execution issue in Rockwell Automation Arena. According to the CISA CSAF advisory, the flaw is caused by improper validation of user-supplied data that allows a write outside the allocated memory buffer. If exploited, it can disclose information and execute arbitrary code on the affected system. The advisory was initially published on 2025-04-10 and later revise [truncated]
CVE-2025-2287 is a high-severity local code execution vulnerability in Rockwell Automation Arena affecting version 16.20.08 and earlier. CISA’s advisory says the flaw stems from an uninitialized pointer and improper validation of user-supplied data. If a legitimate user opens a malicious DOE file, an attacker may be able to disclose information and execute arbitrary code on the system. The safest response [truncated]
CVE-2025-2286 is a high-severity local code execution vulnerability in Rockwell Automation Arena. CISA’s advisory says the issue stems from an uninitialized pointer and improper validation of user-supplied data; exploitation requires a legitimate user to open a malicious DOE file. Rockwell Automation recommends upgrading to V16.20.09 or later.
CVE-2025-2285 is a high-severity local code execution issue in Rockwell Automation Arena. According to CISA’s advisory, the flaw stems from improper validation of user-supplied data and an uninitialized pointer. If a legitimate user opens a malicious DOE file, an attacker may be able to disclose information and execute arbitrary code on the system. Rockwell Automation recommends upgrading to Arena V16.20.09 or later.
CVE-2025-23120 is a critical remote code execution vulnerability in Veeam Backup and Replication that affects Rockwell Automation Industrial Data Center (IDC) with Veeam and VersaVirtual Appliance (VVA) with Veeam. CISA’s CSAF advisory says exploitation can allow a threat actor to execute code on the target system. Rockwell lists affected IDC generations 1 through 5 and VVA series A through C, and directs [truncated]
CVE-2025-1449 is a critical vulnerability in Rockwell Automation Verve Asset Manager affecting versions up to 1.39. In the Legacy Active Directory Interface (ADI) administrative web interface, an inadequately sanitized variable can be modified by an authenticated administrative user, creating a path to arbitrary command execution in the container running the service. Rockwell Automation reports the issue [truncated]
Rockwell Automation PowerFlex 755 is affected by a credential-exposure issue in which HTTP is used and credentials can be sent in clear text. In an OT environment, that creates a straightforward confidentiality risk for anyone able to observe traffic on the network path.
CVE-2025-24478 is a denial-of-service vulnerability in Rockwell Automation GuardLogix 5380 and 5580 controllers. According to CISA’s advisory, a remote, non-privileged user can send malicious requests that trigger a major nonrecoverable fault, taking the affected controller out of service. Rockwell and CISA recommend updating to the fixed versions and applying OT access controls where possible.