PatchSiren

PatchSiren cyber security CVE debrief

CVE-2025-3285 Rockwell Automation CVE debrief

CVE-2025-3285 affects Rockwell Automation Arena and is rated CVSS 7.8 (High). CISA’s advisory describes a local code execution flaw caused by improper validation of user-supplied data, allowing a read outside the allocated memory buffer. In practical terms, a legitimate user must open a malicious DOE file for the issue to be triggered, and successful exploitation could disclose information and execute arbitrary code on the system. The advisory was published on 2025-04-10 and later revised on 2025-05-06 for typo fixes only.

Vendor
Rockwell Automation
Product
Arena
CVSS
HIGH 7.8
CISA KEV
Not listed in stored evidence
Original CVE published
2025-04-10
Original CVE updated
2025-05-06
Advisory published
2025-04-10
Advisory updated
2025-05-06

Who should care

Organizations running Rockwell Automation Arena, especially versions up to 16.20.08, should care most. This includes OT/ICS operators, plant engineers, endpoint security teams, and anyone responsible for reviewing file-handling risk on systems where users may open DOE files.

Technical summary

CISA’s CSAF advisory lists Rockwell Automation Arena: <=16.20.08 as affected. The weakness is described as improper validation of user-supplied data leading to a read outside the allocated memory buffer. The CVSS v3.1 vector provided by the advisory is AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H, reflecting local exploitation conditions and required user interaction. The source text states that a legitimate user must open a malicious DOE file, and the impact can include information disclosure and arbitrary code execution.

Defensive priority

High priority for systems that use Arena and handle untrusted or externally supplied DOE files. The required user interaction lowers immediacy compared with fully remote flaws, but the potential impact is severe and the affected version range is broad.

Recommended defensive actions

  • Upgrade Rockwell Automation Arena to version 16.20.09 or later.
  • Restrict and carefully review DOE files before opening them on systems running Arena.
  • Apply Rockwell Automation’s published security best practices for industrial automation control systems.
  • Use CISA ICS recommended practices to reduce exposure on OT/ICS assets.
  • Limit user permissions and isolate engineering workstations where feasible to reduce the impact of a successful exploit.

Evidence notes

All substantive claims are taken from the CISA CSAF advisory ICSA-25-100-07 and its embedded product/remediation fields. The advisory states the affected product as Rockwell Automation Arena: <=16.20.08, describes the issue as a local code execution vulnerability from improper validation of user-supplied data, and notes that exploitation requires a legitimate user to open a malicious DOE file. The advisory was initially published on 2025-04-10 and revised on 2025-05-06 for typo fixes.

Sources and references

Verified primary and authoritative sources

  • CVE-2025-3285 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2025-3285

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2025-3285 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2025-3285

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source item URL

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-100-07.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-100-07

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ncas/tips/ST04-014

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Reference

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.