CVE-2025-3285 Rockwell Automation CVE debrief
CVE-2025-3285 affects Rockwell Automation Arena and is rated CVSS 7.8 (High). CISA’s advisory describes a local code execution flaw caused by improper validation of user-supplied data, allowing a read outside the allocated memory buffer. In practical terms, a legitimate user must open a malicious DOE file for the issue to be triggered, and successful exploitation could disclose information and execute arbitrary code on the system. The advisory was published on 2025-04-10 and later revised on 2025-05-06 for typo fixes only.
- Vendor
- Rockwell Automation
- Product
- Arena
- CVSS
- HIGH 7.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-04-10
- Original CVE updated
- 2025-05-06
- Advisory published
- 2025-04-10
- Advisory updated
- 2025-05-06
Who should care
Organizations running Rockwell Automation Arena, especially versions up to 16.20.08, should care most. This includes OT/ICS operators, plant engineers, endpoint security teams, and anyone responsible for reviewing file-handling risk on systems where users may open DOE files.
Technical summary
CISA’s CSAF advisory lists Rockwell Automation Arena: <=16.20.08 as affected. The weakness is described as improper validation of user-supplied data leading to a read outside the allocated memory buffer. The CVSS v3.1 vector provided by the advisory is AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H, reflecting local exploitation conditions and required user interaction. The source text states that a legitimate user must open a malicious DOE file, and the impact can include information disclosure and arbitrary code execution.
Defensive priority
High priority for systems that use Arena and handle untrusted or externally supplied DOE files. The required user interaction lowers immediacy compared with fully remote flaws, but the potential impact is severe and the affected version range is broad.
Recommended defensive actions
- Upgrade Rockwell Automation Arena to version 16.20.09 or later.
- Restrict and carefully review DOE files before opening them on systems running Arena.
- Apply Rockwell Automation’s published security best practices for industrial automation control systems.
- Use CISA ICS recommended practices to reduce exposure on OT/ICS assets.
- Limit user permissions and isolate engineering workstations where feasible to reduce the impact of a successful exploit.
Evidence notes
All substantive claims are taken from the CISA CSAF advisory ICSA-25-100-07 and its embedded product/remediation fields. The advisory states the affected product as Rockwell Automation Arena: <=16.20.08, describes the issue as a local code execution vulnerability from improper validation of user-supplied data, and notes that exploitation requires a legitimate user to open a malicious DOE file. The advisory was initially published on 2025-04-10 and revised on 2025-05-06 for typo fixes.
Sources and references
Verified primary and authoritative sources
-
CVE-2025-3285 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2025-3285
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2025-3285 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2025-3285
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-100-07.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-100-07
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ncas/tips/ST04-014
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.