CVE-2025-2285 Rockwell Automation CVE debrief
CVE-2025-2285 is a high-severity local code execution issue in Rockwell Automation Arena. According to CISA’s advisory, the flaw stems from improper validation of user-supplied data and an uninitialized pointer. If a legitimate user opens a malicious DOE file, an attacker may be able to disclose information and execute arbitrary code on the system. Rockwell Automation recommends upgrading to Arena V16.20.09 or later.
- Vendor
- Rockwell Automation
- Product
- Arena
- CVSS
- HIGH 7.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-04-10
- Original CVE updated
- 2025-05-06
- Advisory published
- 2025-04-10
- Advisory updated
- 2025-05-06
Who should care
Organizations using Rockwell Automation Arena, especially environments where users may open externally supplied DOE files. Industrial automation and control-system teams should treat this as a priority because successful exploitation requires user interaction but can lead to code execution on an affected workstation or engineering system.
Technical summary
CISA’s CSAF advisory identifies Rockwell Automation Arena <=16.20.08 as affected. The issue is described as a local code execution vulnerability caused by an uninitialized pointer and improper validation of user-supplied data. The published CVSS vector is CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H, with a score of 7.8 (High). Exploitation requires a legitimate user to open a malicious DOE file, which makes this a user-interaction-dependent attack path rather than a remotely triggerable one.
Defensive priority
High for affected Arena deployments. The combination of code execution potential, information disclosure, and the likelihood of user-driven exposure makes patching and file-handling controls important even though the attacker must first get a user to open a malicious file.
Recommended defensive actions
- Upgrade Rockwell Automation Arena to V16.20.09 or later.
- Restrict and inspect DOE files received from outside trusted sources before opening them.
- Apply industrial control system security best practices from Rockwell Automation and CISA to reduce exposure.
- Limit which users can open engineering or simulation files on systems used for Arena.
- Track CISA advisory ICSA-25-100-07 and Rockwell Automation advisory SD1726 for any further guidance.
Evidence notes
All core claims are drawn from the supplied CISA CSAF record for ICSA-25-100-07 and its referenced Rockwell Automation mitigation guidance. The advisory was published on 2025-04-10 and revised on 2025-05-06 for typo fixes only. Affected product scope is Rockwell Automation Arena <=16.20.08. Recommended remediation is upgrade to V16.20.09 or later. No exploit details beyond the advisory’s user-interaction requirement are included.
Sources and references
Verified primary and authoritative sources
-
CVE-2025-2285 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2025-2285
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2025-2285 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2025-2285
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-100-07.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-100-07
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ncas/tips/ST04-014
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.