CVE-2024-6351 is a medium-severity Schneider Electric Zigbee advisory issue published by CISA on 2026-01-13. The disclosed weakness is a CWE-120 buffer overflow that can cause a denial of service when a malicious device joins the network. The published CVSS vector (4.3, AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L) indicates adjacent-network conditions and availability-only impact.
CVE-2024-6350 is a medium-severity buffer overflow issue in Schneider Electric Zigbee products, including Wiser iTRV2. According to the advisory, a malicious device joining the network could trigger a denial of service. The published mitigations focus on tightening Zigbee pairing and access controls rather than on exploit details.
CVE-2024-10106 is a low-severity availability issue in Schneider Electric Wiser Zigbee products. The advisory says a CWE-120 buffer overflow can cause denial of service if a malicious device joins the network. The published CVSS vector (AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L) indicates network reachability, no privileges, and limited availability impact, with no confidentiality or integrity impact identified in the supplied sources.
CVE-2025-9317 affects Schneider Electric software tied to AVEVA components, including EcoStruxure Machine SCADA Expert and Pro-face BLUE Open Studio. The disclosed issue centers on passwords being stored as MD5 hashes, which could let an attacker with read access to Edge Project files or Edge Offline Cache files recover app-native or Active Directory passwords through computational brute-force attacks against weak hashes. The advisory was published on 2025-11-11 and is rated High severity with a CVSS v3.1 score of 8.4.
CVE-2025-11567 is a high-severity local privilege-risk issue in Schneider Electric PowerChute Serial Shutdown. According to the CISA CSAF advisory, the flaw is a CWE-276 incorrect default permissions problem that could allow elevated system access when the target installation folder is not properly secured. Schneider Electric states that version v1.4 includes a fix, and recommends applying the update and securing any custom installation folder with administrative permissions.
CVE-2025-11566 is a HIGH-severity authentication weakness in Schneider Electric PowerChute Serial Shutdown. CISA’s advisory says a local-network attacker could make an arbitrary number of authentication attempts with different credentials against the /REST/shutdownnow endpoint and potentially gain access to the user account. Schneider Electric lists version v1.4 as the fixed release.
CVE-2025-11565 is a high-severity path traversal vulnerability in Schneider Electric PowerChute™ Serial Shutdown. According to the advisory, a Web Admin user on the local network can tamper with the POST /REST/UpdateJRE request payload and trigger elevated system access. Schneider Electric says version v1.4 includes a fix.
Schneider Electric Saitel DR & Saitel DP Remote Terminal Unit has a CWE-78 vulnerability that could cause command injection in BLMon when in a SSH session. This vulnerability exists in Schneider Electric Saitel DR RTU Versions 11.06.29 and prior and Saitel DP RTU Versions 11.06.33 and prior. Defenders should assess exposure and apply firmware updates. The vulnerability allows for command injection in BLMon that is executed in the operating system console when in a SSH session. The vulnerability has a medium severity and defenders should verify and apply firmware updates to prevent command injection, restrict access to BLMon to prevent unauthorized command execution, and implement
CVE-2025-8449 is a CWE-400: Uncontrolled Resource Consumption vulnerability in Schneider Electric's EcoStruxure Building Operation Enterprise Server. An authenticated user can cause a denial of service by sending a specially crafted request to a specific endpoint within the BMS network. This vulnerability exists in multiple versions of EcoStruxure Building Operation Enterprise Server, Enterprise Central, and Workstation. Defenders should assess exposure and apply patches or mitigations to prevent potential denial of service attacks.
A high-severity Improper Link Resolution Before File Access vulnerability exists in Schneider Electric's SESU, which could allow an attacker to write arbitrary data to protected locations, potentially leading to escalation of privilege, file corruption, exposure of application and system information, or persistent denial of service. The vulnerability is rated with a CVSS score of 7.3 and has a HIGH severity. The affected products include various Schneider Electric SESU versions prior to 3.0.12 installed on multiple platforms.
CVE-2024-28219 is represented in the supplied CSAF source as an Industrial Control Systems advisory for Schneider Electric EcoStruxure Power Operation (EPO) 2022 and 2024, with a CVSS 3.1 score of 6.7 (MEDIUM). The advisory context indicates affected deployments should move to the vendor-provided remediation path and review PostgreSQL-related mitigation steps if full patching is not immediately possible. The source corpus also contains a separate vulnerability description that references Pillow prior to 10.3.0, so the advisory/product mapping should be validated against the official Schneider Electric and CISA references before operational use.
The supplied CISA CSAF advisory maps CVE-2022-45198 to Schneider Electric EcoStruxure Power Operation (EPO) 2022 and 2024, with affected versions listed as EPO 2022 <=CU6 and EPO 2024 <=CU1. The record rates the issue 7.5 (High) with network access, no privileges, no user interaction, and availability impact only. The source corpus also says, "Versions of Pillow before 9.2.0 improperly handle highly compressed GIF data (data amplification)," which creates an apparent product/vulnerability mismatch in the published advisory; use the remediation guidance in the advisory and verify applicability against your installed EPO version.
CVE-2025-6788 is a medium-severity access control issue in Schneider Electric EcoStruxure Power Monitoring Expert (PME) and EcoStruxure Power Operation (EPO) Advanced Reporting and Dashboards Module. According to CISA’s CSAF advisory, TGML diagram resources can be exposed to the wrong control sphere, which may allow other authenticated users to access diagrams they should not see. Schneider Electric provides hotfixes for the affected versions and also recommends removing TGML diagrams from multitenant managed or on-premises systems and reverting to Vista diagrams if remediation is deferred.
CVE-2025-6438 is a CWE-611 XML External Entity (XXE) issue in Schneider Electric EcoStruxure™ IT Data Center Expert. According to the CISA advisory and Schneider Electric notice, the flaw can affect SOAP API handling and may lead to unauthorized file access when the server is accessed over the network using an application account. Schneider Electric states that version 9.0 includes the fix, and CISA published the advisory on 2025-07-08.
CVE-2025-50125 is a CWE-918 server-side request forgery issue in Schneider Electric EcoStruxure™ IT Data Center Expert. CISA and Schneider Electric describe it as network-accessible and unauthenticated, with the potential to reach remote code execution when an attacker knows hidden URLs and can manipulate the Host request header. The advisory published on 2025-07-08 rates the issue HIGH with CVSS 7.2.
CVE-2025-50124 is a Schneider Electric EcoStruxure IT Data Center Expert issue described as CWE-269 improper privilege management. According to the CISA CSAF advisory and the vendor notice, it could lead to privilege escalation when the server is accessed by a privileged account via a console and through exploitation of a setup script. Schneider Electric lists version 9.0 as the fixed release for EcoStruxure IT Data Center Expert, while affected products include version 8.3 and prior.
CVE-2025-50123 is a CWE-94 code injection issue in Schneider Electric EcoStruxure™ IT Data Center Expert. According to the vendor and CISA advisory, affected versions are 8.3 and earlier, and exploitation could cause remote command execution by a privileged account when the server is accessed via a console and the hostname input is abused. Schneider Electric states that version 9.0 includes fixes.
CVE-2025-50122 is a high-severity issue in Schneider Electric EcoStruxure IT Data Center Expert version 8.3 and earlier. According to the advisory, access to installation or upgrade artifacts could enable reverse engineering of the password generation algorithm and lead to root password discovery.
CVE-2025-50121 is a critical OS command injection vulnerability in Schneider Electric EcoStruxure™ IT Data Center Expert. According to the CISA CSAF advisory published on 2025-07-08, the issue could allow unauthenticated remote code execution when a malicious folder is created through the web interface over HTTP, if HTTP is enabled. Schneider Electric states that HTTP is disabled by default, which reduces exposure, but any environment that has enabled HTTP should treat this as urgent.
CVE-2025-5743 is a medium-severity OS command injection issue in Schneider Electric EVLink WallBox. According to the vendor and CISA advisory, an authenticated user who changes web-server configuration parameters may gain remote control of the charging station. The product is end-of-life, so Schneider Electric does not list a traditional fix for the affected line and instead recommends mitigation plus migration to EVLink Pro AC.
CVE-2025-5742 is a medium-severity cross-site scripting issue in Schneider Electric EVLink WallBox. According to the advisory, an authenticated user can modify configuration parameters on the web server in a way that allows improper input handling during page generation. The affected product is listed as EVLink WallBox all versions, and Schneider Electric notes the product has reached end of life with no fix planned. The primary defensive path is to reduce exposure of the device web interface, tighten access control, and move to the replacement product where feasible.
CVE-2025-5741 affects Schneider Electric EVLink WallBox all versions. It is a CWE-22 path traversal issue that could allow arbitrary file reads from the charging station, but exploitation requires an authenticated web server session. Because the product is end of life, Schneider Electric states that no fix is planned; the recommended response is to restrict access, segment the network, review logs, and migrate to the replacement EVLink Pro AC.
CVE-2025-5740 is a high-severity CWE-22 path traversal issue in Schneider Electric EVLink WallBox. The advisory states that an authenticated user on the web server can manipulate a file path and cause arbitrary file writes. CISA updated the advisory on 2025-07-08 to clarify that authentication is required. Schneider Electric lists EVLink WallBox as end of life and says no fix is planned, so owners should focus on containment, access restriction, and migration planning.
CVE-2025-3905 is a cross-site scripting vulnerability in Schneider Electric Modicon controller web interfaces that can let an authenticated malicious user inject unvalidated data into PLC system variables and influence what a victim’s browser reads or modifies. CISA published the advisory on 2025-06-10 and updated it on 2025-07-08 when remediation became available for the M241/M251 path. The advisory remains important for environments that expose controller web services or rely on browser-based administration.
CVE-2025-3899 is a medium-severity cross-site scripting issue in the webserver Certificates page used by Schneider Electric Modicon Modicon Controllers M241 and M251. According to the advisory, an authenticated malicious user could inject unvalidated data and cause a victim’s browser to read or modify data. Schneider Electric and CISA list a fixed release and mitigations, and the advisory was updated on 2025-07-08 to note remediation availability.
CVE-2025-3898 is a medium-severity denial-of-service vulnerability in Schneider Electric Modicon Controllers. According to the CISA CSAF advisory, an authenticated malicious user can send an HTTPS request containing an invalid data type to the webserver and cause the service to fail. The advisory was originally published on 2025-06-10 and revised on 2025-07-08 to note that remediation was available for update paths using EcoStruxure Machine Expert v2.3.
CVE-2025-3117 is a CWE-79 cross-site scripting vulnerability in Schneider Electric Modicon controller web configuration paths. According to the CISA CSAF advisory and Schneider Electric notice, an authenticated malicious user could inject unvalidated data that may let them modify or read data in a victim’s browser. The issue affects Modicon M241, M251, M262, M258, and LMC058. Vendor fixes are available for M241, M251, and M262; M258 and LMC058 are listed as awaiting a future remediation plan, so mitigations matter immediately for those products.
CVE-2025-3116 is a medium-severity denial-of-service issue in Schneider Electric Modicon controllers. According to the advisory, an authenticated malicious user can send a specially malformed HTTPS request with improperly formatted body data to the controller and trigger a service disruption. Schneider Electric later updated the notice to say a remediation is available for M241 and M251, while M258 and LMC058 had mitigation guidance only in the supplied source corpus.
CVE-2025-3112 is a CWE-400 uncontrolled resource consumption issue in Schneider Electric Modicon Controllers M241 and M251. According to the CISA CSAF advisory, an authenticated malicious user can send a manipulated HTTPS Content-Length header to the webserver and cause denial of service. The advisory lists affected versions prior to 5.3.12.51 and notes that remediation is available.
A CWE-121 Stack-based Buffer Overflow vulnerability exists in Schneider Electric EcoStruxure Power Build Rapsody that could cause local attackers to potentially execute arbitrary code while the end user opens a malicious project file (SSD file) provided by the attacker. This issue affects product versions prior to v2.8.2 FR. Defenders should assess exposure and prioritize verification and remediation efforts accordingly. The vulnerability has a CVSS score of 5.3 and a severity of MEDIUM.