These pages are published after PatchSiren validates generated defensive summaries against stored public CVE and source evidence.
A flaw in Node.js Permission Model enforcement allows process.report writes (and overwrites) files outside --allow-fs-write paths. This can lead to confidentiality impact or bypass of the intended security boundary under affected configurations. The vulnerability affects Node.js 22.x, 24.x, and 26.x. Defenders and administrators responsible for Node.js installations should be aware of this vulnerability and take steps to verify their configurations and mitigate potential risks. This includes reviewing process.report usage, ensuring --allow-fs-write paths are properly configured, and monitoring for suspicious activity. The CVE record and NVD entry provide limited information about the vulnerability. Further investigation is needed to determine the full scope of affected configurations and potential mitigations.
The CVE-2026-58043 vulnerability in Node.js arises from a flaw in the Permission Model enforcement, leading to over-granted filesystem access across radix-tree prefix boundaries. This issue affects Node.js main, 22.x, 24.x, and 26.x versions. The vulnerability allows an attacker granted access to one path to exploit boundary handling and read from or write to paths outside the intended filesystem allowlist. Users are advised to apply patches to mitigate this high-severity vulnerability. The flaw has been identified in official CVE and NVD records, emphasizing the need for affected users to take immediate action. To further assess and mitigate this vulnerability, defenders should review official CVE and NVD details, verify Node.js deployments against affected versions, and monitor for potential filesystem access anomalies. Evidence is based on official records, and users should verify their Node.js versions and apply patches. This vulnerability has not been modified since its publication on 2026-07-30T06:25:55.310Z.
CVE-2026-58040 is an incomplete fix for CVE-2026-48934 in Node.js, affecting versions 22.x, 24.x, and 26.x. The vulnerability involves HTTPS Agent TLS session reuse skipping hostname verification across identity policies. Node.js users and administrators should assess and remediate this vulnerability. The CVE record was published on 2026-07-30T06:25:55.190Z and has not been modified since then. This incomplete fix may allow for potential security risks if not properly addressed.
A flaw in Node.js HTTPS Agent connection reuse can cause PFX object-array key collisions, allowing mutual TLS (mTLS) client identities to be reused across requests configured with different client certificates. This vulnerability affects Node.js 26.x, 24.x, and 22.x. The vulnerability allows an attacker to potentially bypass security controls and access sensitive information. Organizations using Node.js versions 26.x, 24.x, and 22.x should prioritize remediation efforts. The CVE record and NVD entry provide details on the vulnerability. However, additional information from other sources is limited. Defenders should verify the affected Node.js versions (26.x, 24.x, and 22.x) and review the vendor advisory for mitigation guidance.
The CVE-2026-56847 vulnerability involves a flaw in the Node.js Permission Model enforcement, specifically allowing `trace_events.createTracing().enable()` to write trace logs outside of the `--allow-fs-write` directive. This can lead to a confidentiality impact or bypass of the intended security boundary under affected configurations. The vulnerability affects Node.js versions 22.x, 24.x, and 26.x. Organizations and developers using these versions should be aware of this vulnerability and take necessary actions to mitigate the risk. The CVE record was published on 2026-07-30T06:25:54.953Z and has not been modified since then.
The undici library's setCookie function does not fully sanitize cookie attributes, allowing attacker-influenced input to inject additional attributes. This issue affects undici versions before 6.28.0, 7.29.0, and 8.9.0. The vulnerability can lead to SameSite CSRF protections bypass and attribute manipulation. Affected applications pass user-controlled input to cookie attributes, such as multi-tenant or reverse-proxy servers that scope session cookies to a tenant-supplied domain. The issue is fixed in undici 6.28.0, 7.29.0, and 8.9.0. Evidence is limited to public CVE and NVD details. Defenders should verify undici usage, review cookie attribute handling, and monitor for potential SameSite CSRF protections bypass and attribute manipulation.
A flaw in Node.js TLS host verification can cause an attacker to bypass certification validation. This vulnerability affects all supported release lines: Node.js 22, Node.js 24, and Node.js 26. The Common Vulnerabilities and Exposures (CVE) score for this vulnerability is 4.3, with a Medium severity rating. The vulnerability was published on June 26, 2026, and last modified on June 29, 2026. Node.js has released security patches for this vulnerability.
A flaw was found in the Node.js WebCrypto implementation. The vulnerability occurs when the input to `subtle.encrypt()` is a multiple of 2GiB, causing the process to crash. This issue affects all supported release lines of Node.js, specifically Node.js 22, Node.js 24, and Node.js 26. The Common Vulnerabilities and Exposures (CVE) score for this vulnerability is 7.5, with a severity rating of HIGH. The CVE was published on June 26, 2026, and modified on June 30, 2026.
A memory leak occurs in Node.js HTTP/2 servers when a client sends WINDOW_UPDATE frames on stream 0, causing the flow control window to exceed the maximum value of 2³¹-1. The server sends a GOAWAY frame but fails to clean up the Http2Session object. This vulnerability affects Node.js versions 20, 22, 24, and 25, potentially exposing these systems to memory leaks. The technical impact involves increased memory usage, which could lead to performance degradation or crashes if exploited repeatedly. Node.js users and administrators, especially those using affected versions, should be aware of this medium-severity vulnerability and take steps to mitigate it. This includes reviewing their deployments for affected versions, prioritizing patching, and monitoring for potential exploitation attempts.
A flaw exists in Node.js Permission Model network enforcement, leaving Unix Domain Socket (UDS) server operations without required permission checks. Code running under `--permission` without `--allow-net` can create and expose local IPC endpoints, allowing communication with other processes on the same host outside of the intended network restriction boundary. This affects Node.js 25.x processes using the Permission Model where `--allow-net` is intentionally omitted.
CVE-2026-21710 is a flaw in Node.js HTTP request handling that causes an uncaught TypeError when a request is received with a header named __proto__ and the application accesses req.headersDistinct. This occurs because dest[__proto__] resolves to Object.prototype rather than undefined, causing .push() to be called on a non-array. The exception is thrown synchronously inside a property getter and cannot be intercepted by error event listeners. This vulnerability affects all Node.js HTTP servers on 20.x, 22.x, 24.x, and v25.x.
CVE-2026-2229 is a high-severity vulnerability in the undici WebSocket client, allowing for a denial-of-service attack due to improper validation of the server_max_window_bits parameter in the permessage-deflate extension. A malicious server can respond with an out-of-range server_max_window_bits value, causing the client to crash. The vulnerability exists due to inadequate validation and exception handling in the isValidClientWindowBits function and createInflateRaw call. This issue affects undici versions prior to 6.24.0 and 7.24.0.
CVE-2026-1528 is a high-severity vulnerability in the Node.js Undici library. The vulnerability occurs when a server replies with a WebSocket frame using the 64-bit length form and an extremely large length, causing undici's ByteParser to overflow internal math, resulting in an invalid state and a fatal TypeError that terminates the process. The vulnerability was patched in undici versions v7.24.0 and v6.24.0. Users are advised to upgrade to these versions or later. The Common Vulnerability Scoring System (CVSS) score for this vulnerability is 7.5, indicating a high severity. The CVSS vector is CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H.
CVE-2026-1526 is a high-severity denial-of-service vulnerability in the undici WebSocket client. The vulnerability exists in the PerMessageDeflate.decompress() method, which accumulates all decompressed chunks in memory and concatenates them into a single Buffer without checking whether the total size exceeds a safe threshold. A malicious WebSocket server can send a small compressed frame that expands to an extremely large size in memory, causing the Node.js process to exhaust available memory and crash or become unresponsive. The vulnerability has a CVSS score of 7.5 and is considered high severity. The CVE was published on March 12, 2026, and modified on June 30, 2026
CVE-2025-55131 is a high-severity vulnerability in Node.js that exposes uninitialized memory when allocations are interrupted, potentially leaking in-process secrets or causing data corruption. The flaw is related to the buffer allocation logic and can be exploited under specific timing conditions. This vulnerability affects Node.js versions and can be triggered when using the `vm` module with the timeout option. The vulnerability has a CVSS score of 7.1 and is considered high severity. Exploitation typically requires precise timing or in-process code execution but can become remotely exploitable under certain conditions.
CVE-2025-55130 is a critical vulnerability in Node.js's Permissions model. This flaw allows attackers to bypass `--allow-fs-read` and `--allow-fs-write` restrictions using crafted relative symlink paths. By chaining directories and symlinks, a script granted access only to the current directory can escape the allowed path and read sensitive files. This breaks the expected isolation guarantees and enables arbitrary file read/write, leading to potential system compromise. The vulnerability affects users of the permission model on Node.js v20, v22, v24, and v25.
Node.js is vulnerable to a denial of service, caused by an assertion failure in `node::http2::Http2Session::~Http2Session()`. By sending a small amount of HTTP/2 frames packets with a few HTTP/2 frames inside, an attacker could exploit this vulnerability to cause the HTTP/2 server to crash. This issue affects Node.js and SINEC INS systems, which defenders should prioritize verifying for exposure and apply patches or mitigations as available. The vulnerability has a CVSS score of 7.5 and is considered HIGH severity.
A vulnerability in the http server of Siemens SINEC INS allows for HTTP request smuggling due to incorrect interpretation of malformed headers, specifically when a space is placed before a content-length header. This issue enables attackers to smuggle a second request within the body of the first. The vulnerability has a medium severity and affects Siemens SINEC INS systems. Defenders should assess exposure and prioritize verification and updates to prevent potential HTTP request smuggling attacks.
CVE-2024-24758 describes an information disclosure vulnerability in Undici, an HTTP/1.1 client for Node.js. While Undici properly clears Authorization headers during cross-origin redirects, it fails to clear Proxy-Authentication headers, potentially exposing proxy credentials to unintended destinations. This vulnerability affects Siemens SINEC INS, which incorporates the vulnerable Undici component. The issue was published on November 12, 2024, with patches available in Undici versions 5.28.3 and 6.6.1. Siemens has released V1.0 SP2 Update 3 to address this in their product. The CVSS 3.1 score of 3.9 (Low severity) reflects the attack complexity requirements: network access with high attack complexity, high privileges required, and user interaction needed. No known workarounds exist; patching is the only remediation. This vulnerability is not listed in CISA's Known Exploited Vulnerabilities catalog.
CVE-2024-22025 is a denial-of-service vulnerability in Node.js affecting Siemens SINEC INS, published 2024-11-12. The vulnerability stems from resource exhaustion during fetch() brotli decoding, where a remote attacker can send a specially crafted request to trigger a DoS condition. The CVSS 3.1 score of 5.3 (MEDIUM) reflects network accessibility with low attack complexity, no required privileges or user interaction, and low availability impact. Siemens has released a vendor fix: update to V1.0 SP2 Update 3 or later. CISA published this advisory as ICSA-24-319-08, cross-referencing Siemens' security advisory SSA-915275.
A vulnerability in Node.js allows processes to perform privileged operations despite having dropped privileges through a call to setuid(). This affects users of Node.js versions 18.18.0, 20.4.0, and 21. The vulnerability is caused by libuv's internal io_uring operations not being affected by setuid() if initialized before the call. This allows processes to perform privileged operations despite presumably having dropped such privileges. System administrators and developers using affected Node.js versions should assess exposure and prioritize updates.
CVE-2024-21896 is a high-severity directory traversal vulnerability affecting Siemens SINEC INS, published on 2024-11-12. The vulnerability stems from Node.js Buffer internals manipulation, specifically through monkey-patching `Buffer.prototype.utf8Write`. An attacker exploiting this flaw can craft URL requests containing path traversal sequences (/../) to read arbitrary files on the affected system. The CVSS 3.1 score of 7.9 reflects significant confidentiality and integrity impact, though availability is not affected. Siemens has released a vendor fix in V1.0 SP2 Update 3 or later versions. This vulnerability is not currently listed in CISA's Known Exploited Vulnerabilities catalog.
CVE-2024-21892 is a high-severity local privilege escalation vulnerability affecting Node.js, as used in Siemens SINEC INS. The flaw stems from a bug in the implementation of the CAP_NET_BIND_SERVICE capability exception, which could allow a local authenticated attacker to inject code that inherits the process's elevated privileges. The vulnerability was published on November 12, 2024, via CISA's ICS advisory ICSA-24-319-08, which references Siemens' security advisory SSA-915275. Siemens has released a vendor fix: users should update to SINEC INS V1.0 SP2 Update 3 or later. The CVSS 3.1 score of 7.8 reflects high impacts to confidentiality, integrity, and availability, with a local attack vector and low attack complexity. This vulnerability is not listed in CISA's Known Exploited Vulnerabilities catalog.
CVE-2024-21891 is a path traversal vulnerability in Node.js that enables remote attackers to bypass filesystem permission models. The vulnerability stems from improper sanitization of path traversal sequences, allowing attackers to access files outside intended directories. Siemens SINEC INS is affected by this vulnerability through its Node.js dependency. CISA published advisory ICSA-24-319-08 on November 12, 2024, coordinating disclosure with Siemens. The vulnerability carries a CVSS 3.1 score of 5.3 (Medium severity) with a network attack vector requiring no privileges or user interaction. Siemens has released SINEC INS V1.0 SP2 Update 3 to address this issue. Organizations should prioritize patching, especially for internet-facing industrial control systems where Node.js components process untrusted input.
CVE-2024-21890 documents a documentation clarity issue in the Node.js Permission Model that could lead to unintended filesystem access. The vulnerability stems from misleading documentation regarding wildcard usage in file path permissions. Specifically, the documentation does not clarify that wildcards should only be used as the last character of a file path. When users specify patterns like `--allow-fs-read=/home/node/.ssh/*.pub`, the system interprets the wildcard to match everything after `.ssh/` rather than only files ending with `.pub`, effectively ignoring the intended file extension restriction. This behavior affects all users of the experimental permission model in Node.js 20 and Node.js 21. The issue is particularly relevant to Siemens SINEC INS deployments that utilize affected Node.js versions. The vulnerability was published on November 12, 2024, with a CVSS 3.1 score of 5.3 (MEDIUM severity). Siemens has released a vendor fix recommending update to V1.0 SP2 Update 3 or later version.
CVE-2023-46809 is a HIGH severity vulnerability (CVSS 7.4) affecting Node.js applications that use unpatched OpenSSL versions for RSA decryption with PKCS #1 v1.5 padding. The vulnerability exposes systems to the Marvin Attack, a timing side-channel attack that can recover private RSA keys. Siemens SINEC INS is affected through its Node.js dependency chain. CISA published advisory ICSA-24-319-08 on November 12, 2024, confirming this vulnerability in industrial control system environments. The attack requires network access and high attack complexity but needs no privileges or user interaction, making it particularly dangerous for exposed services. Successful exploitation enables confidentiality and integrity breaches without availability impact.
CVE-2023-45143 is a LOW-severity vulnerability (CVSS 3.9) affecting Undici, an HTTP/1.1 client for Node.js. The issue involves improper handling of Cookie headers during cross-origin redirects. Prior to version 5.26.2, Undici cleared Authorization headers on cross-origin redirects but failed to clear Cookie headers. While browsers forbid Cookie headers in RequestInit.headers per the Fetch specification, Undici's more liberal header handling created a disconnect that could lead to accidental cookie leakage to third-party sites or malicious actors controlling redirect targets. Siemens SINEC INS is affected by this vulnerability through its use of the vulnerable Undici component. The vulnerability was published on November 12, 2024, and affects SINEC INS prior to V1.0 SP2 Update 3.
CVE-2023-39333 is a medium-severity vulnerability affecting Siemens SINEC INS, published on November 12, 2024. The vulnerability stems from maliciously crafted export names in imported WebAssembly modules that can inject JavaScript code. This injected code may access data and functions beyond the WebAssembly module's intended scope, effectively granting it privileges similar to a JavaScript module. The CVSS 3.1 score of 6.1 reflects network attack vector, low attack complexity, no required privileges, user interaction required, and changed scope with low impacts to confidentiality and integrity. Siemens has provided a vendor fix: update to V1.0 SP2 Update 3 or later version.
CVE-2023-39332 is a critical path traversal vulnerability in Node.js affecting Siemens SINEC INS. The flaw exists because Node.js `node:fs` functions inadequately validate `Uint8Array` objects (excluding `Buffer` instances) for path traversal sequences, allowing attackers to bypass security controls that properly block string-based and `Buffer`-based traversal attempts. This vulnerability is distinct from but related to CVE-2023-32004, which addressed the same issue for `Buffer` objects. At the time of CVE issuance, Node.js's permission model was an experimental feature. The vulnerability enables unauthenticated remote attackers to achieve arbitrary file read, write, and execution capabilities with CVSS 9.8 severity. Siemens has released a vendor fix in SINEC INS V1.0 SP2 Update 3.
CVE-2023-38552 is a high-severity vulnerability (CVSS 7.5) in Node.js's experimental policy mechanism that allows integrity check bypass. When Node.js verifies a resource against a trusted manifest, an attacker can intercept this operation and return a forged checksum, effectively disabling the integrity verification. This vulnerability affects Node.js 18.x and 20.x release lines. The issue was published on November 12, 2024, and affects Siemens SINEC INS, which incorporates the vulnerable Node.js components. Siemens has released a vendor fix in V1.0 SP2 Update 3 or later versions.