PatchSiren cyber security CVE debrief
CVE-2024-21891 NodeJS CVE debrief
CVE-2024-21891 is a path traversal vulnerability in Node.js that enables remote attackers to bypass filesystem permission models. The vulnerability stems from improper sanitization of path traversal sequences, allowing attackers to access files outside intended directories. Siemens SINEC INS is affected by this vulnerability through its Node.js dependency. CISA published advisory ICSA-24-319-08 on November 12, 2024, coordinating disclosure with Siemens. The vulnerability carries a CVSS 3.1 score of 5.3 (Medium severity) with a network attack vector requiring no privileges or user interaction. Siemens has released SINEC INS V1.0 SP2 Update 3 to address this issue. Organizations should prioritize patching, especially for internet-facing industrial control systems where Node.js components process untrusted input.
- Vendor
- NodeJS
- Product
- SINEC INS
- CVSS
- MEDIUM 5.3
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-11-12
- Original CVE updated
- 2024-11-12
- Advisory published
- 2024-11-12
- Advisory updated
- 2024-11-12
Who should care
Organizations operating Siemens SINEC INS for industrial network management; OT security teams managing Node.js-based applications in critical infrastructure; asset owners with internet-exposed industrial control system management interfaces
Technical summary
CVE-2024-21891 is a path traversal vulnerability in Node.js arising from improper sanitization of traversal sequences (e.g., ../). A remote unauthenticated attacker can exploit this to bypass Node.js's filesystem permission model and access restricted files. The vulnerability affects Siemens SINEC INS, an industrial network management system, through its Node.js dependency. The attack requires network access but no privileges or user interaction, with successful exploitation resulting in integrity impact through unauthorized file access. Siemens has addressed this in V1.0 SP2 Update 3. The vulnerability highlights risks in OT environments where Node.js components may process untrusted input without adequate path validation.
Defensive priority
medium
Recommended defensive actions
- Apply Siemens SINEC INS V1.0 SP2 Update 3 or later to remediate the underlying Node.js path traversal vulnerability
- Validate that Node.js applications processing untrusted input implement proper path sanitization and restrict filesystem access using chroot jails or containerization
- Review application configurations to ensure the Node.js permission model is enabled and properly configured to limit filesystem access
- Monitor for anomalous filesystem access patterns in SINEC INS deployments, particularly attempts to access files outside expected application directories
- For systems that cannot be immediately patched, implement network segmentation to restrict access to SINEC INS management interfaces from untrusted networks
Evidence notes
CISA CSAF advisory ICSA-24-319-08 published 2024-11-12; Siemens SSA-915275; CVSS 3.1 vector confirms network-accessible attack with low attack complexity
Sources and references
Verified primary and authoritative sources
-
CVE-2024-21891 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-21891
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-21891 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-21891
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-319-08.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-915275.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-915275.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-319-08
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.