PatchSiren

PatchSiren cyber security CVE debrief

CVE-2025-48021 Yokogawa Electric Corporation CVE debrief

CVE-2025-48021 is a medium-severity availability issue in Yokogawa CENTUM VP R6 and R7 Vnet/IP Interface Package products. According to CISA’s advisory, maliciously crafted packets can cause the Vnet/IP software stack process to terminate. Yokogawa recommends applying the patch software release R1.08.00.

Vendor
Yokogawa Electric Corporation
Product
Yokogawa Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300) <=R1.07.00 Vnet/IP Interface Package for CENTUM VP R7 (VP7C3300)
CVSS
MEDIUM 5.3
CISA KEV
Not listed in stored evidence
Original CVE published
2026-02-26
Original CVE updated
2026-02-26
Advisory published
2026-02-26
Advisory updated
2026-02-26

Who should care

Operators and administrators responsible for Yokogawa CENTUM VP environments, especially systems using the Vnet/IP Interface Package for CENTUM VP R6 (VP6C3300) up to R1.07.00 and CENTUM VP R7 (VP7C3300). Industrial control system teams should prioritize validation, patch planning, and operational monitoring.

Technical summary

The advisory describes an availability-impacting condition where receipt of maliciously crafted packets may terminate the Vnet/IP software stack process. The supplied CVSS 3.1 vector is AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H, which aligns with an adjacent-network, high-complexity denial-of-service style impact focused on availability. The source corpus does not provide exploit details beyond the packet-triggered process termination.

Defensive priority

High for affected OT environments that rely on Vnet/IP connectivity, because a process termination could disrupt industrial communications and availability. Priority should be to confirm product/version exposure and plan remediation during an approved maintenance window.

Recommended defensive actions

  • Confirm whether any CENTUM VP R6 or R7 hosts are running the affected Vnet/IP Interface Package versions identified in the advisory.
  • Apply Yokogawa’s recommended patch software release R1.08.00 where operationally feasible.
  • Coordinate patching through your OT change-management process and validate recovery procedures before deployment.
  • If immediate patching is not possible, contact the local Yokogawa supporting office and follow the vendor advisory for mitigation guidance.
  • Monitor affected systems for unexpected Vnet/IP stack process termination or communication interruptions after exposure to malformed traffic.

Evidence notes

The source advisory states: “If the affected product receives maliciously crafted packets, Vnet/IP software stack process may be terminated.” It also lists the remediation “Yokogawa recommends users apply patch software (R1.08.00).” The provided CVSS vector is CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H, supporting an availability-focused issue with adjacent attack requirements. Published and modified timestamps supplied in the corpus are 2026-02-26T07:00:00.000Z.

Sources and references

Verified primary and authoritative sources

  • CVE-2025-48021 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2025-48021

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2025-48021 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2025-48021

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source item URL

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-057-09.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-057-09

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ncas/tips/ST04-014

    Reference

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.