PatchSiren cyber security CVE debrief
CVE-2023-49900 X-Rite CVE debrief
CVE-2023-49900 is a critical remote code execution vulnerability due to improper sanitization of user input in the SetParameter command. The vulnerability has a CVSS score of 9.8 and is considered critical. The CVE record was published on 2026-07-16T11:16:36.597Z and has not been modified since then. Affected systems may be exposed to remote code execution attacks if not properly patched. Security teams should review vendor advisories and implement compensating controls as needed.
- Vendor
- X-Rite
- Product
- MA-T6
- CVSS
- CRITICAL 9.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-07-16
- Original CVE updated
- 2026-07-16
- Advisory published
- 2026-07-16
- Advisory updated
- 2026-07-16
Who should care
Security teams and administrators responsible for systems using the affected product should be aware of this vulnerability and take immediate action to mitigate the risk. This includes reviewing vendor advisories, implementing compensating controls, and monitoring system logs for suspicious activity.
Technical summary
An unauthenticated remote attacker can perform remote code execution due to incorrectly sanitized user input in the SetParameter command. The vulnerability has a CVSS vector of CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. This vulnerability affects systems using the affected product and may allow attackers to execute arbitrary code remotely.
Defensive priority
High
Recommended defensive actions
- Verify and apply vendor patches or updates
- Implement compensating controls, such as firewalls and intrusion detection systems
- Monitor system logs for suspicious activity
- Conduct regular vulnerability scans and risk assessments
- Review system configurations and ensure proper input validation
Evidence notes
The CVE record was published on 2026-07-16T11:16:36.597Z and has not been modified since then. The NVD entry is currently Received. Evidence is limited to public sources and may not reflect the full scope or impact of the vulnerability. Defenders should verify affected systems and review vendor advisories for specific guidance.
Official resources
-
CVE-2023-49900 CVE record
CVE.org
-
CVE-2023-49900 NVD detail
NVD
-
Source item URL
nvd_modified
- Source reference
AI-assisted PatchSiren debrief based on the supplied source corpus. The CVE record was published on 2026-07-16T11:16:36.597Z and has not been modified since then. The NVD entry is currently Received.