PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-88850 WAGO CVE debrief

A low-privileged remote attacker can abuse an exposed configuration function in WAGO's Web-Based Management (WBM) to modify root-owned PROFIBUS parameters, including device addressing and SSA settings. This allows unauthorized changes to fieldbus-related configuration and violates the intended privilege boundaries within the management interface. The affected products include various WAGO devices with versions less than 4.10.0.

Vendor
WAGO
Product
0751-9x01
CVSS
HIGH 7.2
CISA KEV
Not listed in stored evidence
Original CVE published
2026-11-23
Original CVE updated
2026-11-24
Advisory published
2026-11-23
Advisory updated
2026-11-24

Who should care

Defenders responsible for WAGO devices, specifically those using Web-Based Management (WBM), should assess exposure and prioritize remediation. This includes operators, platform administrators, vulnerability management teams, and security teams who need to verify the inventory of WAGO devices, assess exposure, and apply remediation to prevent unauthorized configuration changes.

Why it matters

Defenders should prioritize verifying the inventory of WAGO devices, assessing exposure, and applying remediation to prevent unauthorized configuration changes.

  • Verify inventory of WAGO devices and assess exposure to unauthorized configuration changes
  • Apply remediation to prevent unauthorized modifications to PROFIBUS parameters
  • Monitor for signs of unauthorized access or changes to fieldbus-related configuration

Technical summary

The Web-Based Management (WBM) authorization model does not properly enforce permissions for all PROFIBUS configuration operations. A low-privileged remote attacker can abuse an exposed configuration function to modify root-owned PROFIBUS parameters, including device addressing and SSA settings. This allows unauthorized changes to fieldbus-related configuration and violates the intended privilege boundaries within the management interface. The affected products include various WAGO devices with versions less than 4.10.0. Defenders should prioritize verifying the inventory of WAGO devices, assessing exposure, and applying the vendor's remediation.

Defensive priority

Defenders should prioritize verifying the inventory of WAGO devices, assessing exposure, and applying the vendor's remediation.

Recommended defensive actions

  • Verify the inventory of WAGO devices and assess exposure
  • Apply the vendor's remediation, specifically updating to version 4.10.0 or later
  • Monitor for unauthorized changes to fieldbus-related configuration
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up

Evidence notes

The CVE record and source item provide details on the vulnerability, affected products, and versions. However, the corpus does not establish specific exploitation instances or remediation steps beyond version updates.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-88850 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-88850

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-88850 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-88850

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.