PatchSiren cyber security CVE debrief
CVE-2024-41936 Vonets CVE debrief
A directory traversal vulnerability in Vonets Industrial WiFi Bridge Relays and WiFi Bridge Repeaters allows unauthenticated remote attackers to read arbitrary files and bypass authentication. The vulnerability affects software versions 3.3.23.6.9 and prior across 14 distinct product models. CISA published this advisory on August 1, 2024, and noted that Vonets has not responded to coordination requests for mitigation.
- Vendor
- Vonets
- Product
- VAR1200-H
- CVSS
- HIGH 7.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-08-01
- Original CVE updated
- 2024-08-01
- Advisory published
- 2024-08-01
- Advisory updated
- 2024-08-01
Who should care
Organizations deploying Vonets WiFi bridge devices in industrial, enterprise, or operational technology environments should prioritize assessment. Security teams responsible for network infrastructure, OT/ICS security practitioners, and managed service providers supporting distributed wireless deployments are most affected. The unauthenticated nature of this vulnerability makes it particularly dangerous for internet-exposed or improperly segmented devices.
Technical summary
The vulnerability is a directory traversal flaw in the web management interface of Vonets Industrial WiFi Bridge products. An unauthenticated remote attacker can exploit path traversal sequences to access files outside the intended directory scope, including sensitive system files. This file read capability can be leveraged to bypass authentication mechanisms. The attack requires no privileges or user interaction and can be executed remotely over the network. The affected firmware version 3.3.23.6.9 and prior are vulnerable across the entire product line of bridge relays and repeaters.
Defensive priority
HIGH
Recommended defensive actions
- Contact Vonets support directly for security updates or mitigation guidance, as the vendor has not coordinated with CISA
- Segment affected devices from untrusted networks and the internet where possible
- Monitor for unauthorized access attempts to Vonets device management interfaces
- Apply network-level access controls to restrict administrative interface access to authorized hosts only
- Consider replacing affected devices if vendor support is unavailable and security patches cannot be obtained
Evidence notes
The source advisory identifies 16 affected product entries spanning 14 unique product models, all running firmware version 3.3.23.6.9 or earlier. The CVSS 3.1 vector (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N) confirms network-based exploitation without authentication requirements.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-41936 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-41936
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-41936 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-41936
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-214-08.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-214-08
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ncas/tips/ST04-014
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.