PatchSiren

PatchSiren cyber security CVE debrief

CVE-2024-41936 Vonets CVE debrief

A directory traversal vulnerability in Vonets Industrial WiFi Bridge Relays and WiFi Bridge Repeaters allows unauthenticated remote attackers to read arbitrary files and bypass authentication. The vulnerability affects software versions 3.3.23.6.9 and prior across 14 distinct product models. CISA published this advisory on August 1, 2024, and noted that Vonets has not responded to coordination requests for mitigation.

Vendor
Vonets
Product
VAR1200-H
CVSS
HIGH 7.5
CISA KEV
Not listed in stored evidence
Original CVE published
2024-08-01
Original CVE updated
2024-08-01
Advisory published
2024-08-01
Advisory updated
2024-08-01

Who should care

Organizations deploying Vonets WiFi bridge devices in industrial, enterprise, or operational technology environments should prioritize assessment. Security teams responsible for network infrastructure, OT/ICS security practitioners, and managed service providers supporting distributed wireless deployments are most affected. The unauthenticated nature of this vulnerability makes it particularly dangerous for internet-exposed or improperly segmented devices.

Technical summary

The vulnerability is a directory traversal flaw in the web management interface of Vonets Industrial WiFi Bridge products. An unauthenticated remote attacker can exploit path traversal sequences to access files outside the intended directory scope, including sensitive system files. This file read capability can be leveraged to bypass authentication mechanisms. The attack requires no privileges or user interaction and can be executed remotely over the network. The affected firmware version 3.3.23.6.9 and prior are vulnerable across the entire product line of bridge relays and repeaters.

Defensive priority

HIGH

Recommended defensive actions

  • Contact Vonets support directly for security updates or mitigation guidance, as the vendor has not coordinated with CISA
  • Segment affected devices from untrusted networks and the internet where possible
  • Monitor for unauthorized access attempts to Vonets device management interfaces
  • Apply network-level access controls to restrict administrative interface access to authorized hosts only
  • Consider replacing affected devices if vendor support is unavailable and security patches cannot be obtained

Evidence notes

The source advisory identifies 16 affected product entries spanning 14 unique product models, all running firmware version 3.3.23.6.9 or earlier. The CVSS 3.1 vector (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N) confirms network-based exploitation without authentication requirements.

Sources and references

Verified primary and authoritative sources

  • CVE-2024-41936 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2024-41936

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2024-41936 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2024-41936

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source item URL

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-214-08.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-214-08

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ncas/tips/ST04-014

    Reference

Methodology and review provenance