HIGH Schneider Electric CVE published 2016-08-07

CVE-2016-8374

CVE-2016-8374 is a high-severity denial-of-service issue affecting multiple Schneider Electric Magelis HMI product families. The weakness is described as uncontrolled resource consumption in a targeted web server, allowing a remote attacker to disrupt availability without authentication or user interaction.

MEDIUM Schneider Electric CVE published 2016-08-07

CVE-2016-8367

CVE-2016-8367 describes a denial-of-service condition in several Schneider Electric Magelis panel firmware families. A remote attacker can open multiple connections to the targeted web server and leave them open, which can block new connections and make the web server unavailable during the attack. The CVE was published on 2017-02-13 and is rated CVSS 3.1 5.3 MEDIUM in the supplied record.

HIGH Schneider Electric CVE published 2016-08-05

CVE-2016-8354

CVE-2016-8354 describes a code-execution flaw in Schneider Electric Unity PRO where Unity projects compiled as x86 instructions can be loaded into the bundled PLC Simulator and executed directly. A specially crafted patched Unity project file can redirect control flow so the simulator runs malicious code. The issue was published on 2017-02-13 and is associated with Unity PRO versions prior to V11.1, with NVD’s CPE data indicating vulnerability through 11.0.

CRITICAL Schneider Electric CVE published 2016-08-05

CVE-2016-8352

CVE-2016-8352 is a critical Schneider Electric ConneXium firewall vulnerability published on 2017-02-13. According to the official record, a stack-based buffer overflow in the SNMP login authentication process can allow remote code execution. The NVD entry rates the issue CVSS 10.0 with network attack vector, no privileges required, no user interaction, and high impact to confidentiality, integrity, and availability.

CRITICAL Schneider Electric CVE published 2016-07-22

CVE-2016-5818

CVE-2016-5818 is a critical authentication flaw in Schneider Electric PowerLogic PM8ECC firmware 2.651 and older. The issue is documented as undocumented hard-coded credentials that can allow access to the device, which is why it is rated 9.8/CRITICAL. Because the condition can enable unauthorized access without needing user interaction, it should be treated as an urgent asset-protection issue for any exposed or deployed PM8ECC systems.