PatchSiren

Belkin CVE debriefs

These pages are published after PatchSiren validates generated defensive summaries against stored public CVE and source evidence.

HIGH Belkin CVE published 2026-04-06

CVE-2026-5629

A stack-based buffer overflow vulnerability was detected in Belkin F9K1015 1.00.10. The affected element is the function formSetFirewall of the file /goform/formSetFirewall. The manipulation of the argument webpage results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used. This vulnerability has a high impact on affected systems, requiring immed [truncated]

HIGH Belkin CVE published 2026-04-06

CVE-2026-5628

A stack-based buffer overflow vulnerability has been detected in Belkin F9K1015 1.00.10. The impacted function is formSetSystemSettings, located in the file /goform/formSetSystemSettings of the Setting Handler component. The manipulation of the argument webpage leads to the vulnerability. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used. The vendor, Be [truncated]

HIGH Belkin CVE published 2026-04-06

CVE-2026-5614

A stack-based buffer overflow vulnerability has been discovered in Belkin F9K1015 1.00.10. The vulnerability exists in the function formSetPassword of the file /goform/formSetPassword. The manipulation of the argument webpage results in a stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early [truncated]

HIGH Belkin CVE published 2026-04-06

CVE-2026-5613

A stack-based buffer overflow vulnerability was identified in Belkin F9K1015 1.00.10. This issue affects the function formReboot of the file /goform/formReboot. The manipulation of the argument webpage leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used. The vulnerability has a high CVSS score of 7.4, indicating a high severity level.

HIGH Belkin CVE published 2026-04-06

CVE-2026-5610

A stack-based buffer overflow vulnerability has been identified in Belkin F9K1015 1.00.10. The issue affects the function formWISP5G of the file /goform/formWISP5G, which can be manipulated remotely via the webpage argument. The exploit has been disclosed publicly. However, the vendor did not respond to early disclosure. Security teams should assess their exposure and prioritize patching.