PatchSiren cyber security CVE debrief
CVE-2026-45449 Unitronics CVE debrief
A high-severity OS command injection vulnerability exists in Unitronics UniStream Pro/UniLogic, specifically affecting Unitronics UniStream Pro versions (B10 / C10) and UniLogic versions prior to 1.41.329. This issue allows attackers to inject OS commands due to improper neutralization of special elements. The vulnerability has a CVSS score of 8.3 and is considered high severity.
- Vendor
- Unitronics
- Product
- Unitronics UniStream Pro/UniLogic
- CVSS
- HIGH 8.3
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-10-15
- Original CVE updated
- 2026-10-15
- Advisory published
- 2026-10-15
- Advisory updated
- 2026-10-15
Who should care
Defenders and security teams responsible for Unitronics UniStream Pro/UniLogic systems, especially those with internet-exposed interfaces, should assess exposure and prioritize verification and potential updates.
Why it matters
CVE-2026-45449 is a high-severity OS command injection vulnerability in Unitronics UniStream Pro/UniLogic. Defenders should prioritize verifying exposure, especially for internet-exposed systems, and assess the need for updates or compensating controls. The vulnerability's high CVSS score of 8.3 indicates significant risk.
- Potential unauthorized access to sensitive data or systems.
- Possible disruption of critical infrastructure or operations.
- Need for verification of system exposure and vulnerability.
- Potential for lateral movement within networks.
Technical summary
The vulnerability exists in Unitronics UniStream Pro/UniLogic due to improper neutralization of special elements used in an OS command. This allows attackers to inject OS commands. The affected products are Unitronics UniStream Pro versions (B10 / C10) and UniLogic versions prior to 1.41.329. Defenders should prioritize verifying exposure of UniStream Pro and UniLogic systems, especially those with internet-exposed interfaces, and assess the need for updates or compensating controls. The vulnerability has a CVSS score of 8.3 and is considered high severity.
Defensive priority
Defenders should prioritize verifying exposure of UniStream Pro and UniLogic systems, especially those with internet-exposed interfaces, and assess the need for updates or compensating controls.
Recommended defensive actions
- Verify exposure of UniStream Pro and UniLogic systems, especially those with internet-exposed interfaces.
- Assess the need for updates or patches to UniLogic version 1.41.329 or later.
- Implement compensating controls, such as restricting access to affected systems or monitoring for suspicious activity.
- Review system configurations and network architecture for potential vulnerabilities.
- Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up.
- Review the supplied official advisory or CVE record to validate affected scope, severity, and vendor guidance.
- Plan vendor-supported updates or mitigations through normal change control where exposure is confirmed.
Evidence notes
The CVE record and source item provide details on the vulnerability, affected products, and CVSS score of 8.3. However, information on exploitation, victims, or specific impacts is not provided. Defenders should verify exposure of UniStream Pro and UniLogic systems, especially those with internet-exposed interfaces, and assess the need for updates or compensating controls. The vulnerability exists in Unitronics UniStream Pro/UniLogic due to improper neutralization of special elements used in an OS command. This allows attackers to OS
Sources and references
Verified primary and authoritative sources
-
CVE-2026-45449 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-45449
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-45449 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-45449
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Unitronics - CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Comm
Unverified legacy reference
URL: https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/45xxx/CVE-2026-45449.json
cve_program_cvelist_v5
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.