PatchSiren cyber security CVE debrief
CVE-2026-131811 United Chargers CVE debrief
A vulnerability in United Chargers Grizzl-E Smart 40A EV chargers allows network-adjacent attackers to bypass authentication due to hard-coded credentials in the OCPP backend settings interface. This could enable attackers to execute arbitrary code on the device. Defenders responsible for EV charger infrastructure should assess their exposure, verify configurations, and apply patches to prevent potential exploitation. The CVE record and source item provide details, but specific version remediation and exploitation details are limited.
- Vendor
- United Chargers
- Product
- Grizzl-E Smart 40A
- CVSS
- HIGH 7.6
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-11-19
- Original CVE updated
- 2026-11-19
- Advisory published
- 2026-11-19
- Advisory updated
- 2026-11-19
Who should care
Defenders responsible for EV charger infrastructure, particularly those using United Chargers Grizzl-E Smart 40A EV chargers, should assess their exposure and verify configurations.
Why it matters
CVE-2026-131811 allows network-adjacent attackers to bypass authentication on United Chargers Grizzl-E Smart 40A EV chargers due to hard-coded credentials. Defenders should verify configurations and apply patches to prevent potential code execution.
- Network-adjacent attackers could bypass authentication on affected Grizzl-E Smart 40A EV chargers
- An attacker could potentially execute arbitrary code in the context of the device
- Defenders need to verify and update charger configurations to prevent exploitation
Technical summary
The vulnerability exists in the OCPP backend settings interface of United Chargers Grizzl-E Smart 40A EV chargers, caused by the use of hard-coded credentials. This allows network-adjacent attackers to bypass authentication. An attacker could potentially leverage this vulnerability, in conjunction with other vulnerabilities, to execute arbitrary code in the context of the device. Defenders should prioritize verifying and updating Grizzl-E Smart 40A EV charger configurations, especially those exposed to network-adjacent access.
Defensive priority
Defenders should prioritize verifying and updating Grizzl-E Smart 40A EV charger configurations, especially those exposed to network-adjacent access.
Recommended defensive actions
- Verify and update Grizzl-E Smart 40A EV charger configurations
- Restrict network access to the OCPP backend settings interface
- Monitor for and apply vendor-provided patches or updates
- Review compensating controls for exposed systems while remediation is scheduled and verified
- Check relevant monitoring, detection, and logs for exposed assets that need extra review
- Track exceptions, retest remediated assets, and close the item only after evidence is documented
- Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up
Evidence notes
The CVE record and source item provide details on the vulnerability, but specific version remediation and exploitation details are limited. Defenders should verify configurations and apply patches to prevent potential code execution. The vulnerability exists in the OCPP backend settings interface, and an attacker could leverage this, along with other vulnerabilities, to execute arbitrary code in the context of the device. Evidence is limited, and defenders should exercise caution when verifying affected scope and applying mitigations.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-131811 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-131811
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-131811 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-131811
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Hard-Coded Credentials Authenticat
Unverified legacy reference
URL: https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/131xxx/CVE-2026-131811.json
cve_program_cvelist_v5
-
Source reference
Unverified legacy reference
URL: https://www.zerodayinitiative.com/advisories/ZDI-26-1032/
Supplemental source - x_research-advisory
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.