PatchSiren cyber security CVE debrief
CVE-2026-54400 Ubiquiti Inc CVE debrief
CVE-2026-54400 is a CRITICAL Improper Access Control vulnerability in UniFi Access Application. A malicious actor with access to the network and high privileges could exploit this vulnerability to escalate privileges on the host device. The vulnerability has a CVSS score of 9.1. The vulnerability is caused by an Improper Access Control issue in UniFi Access Application, allowing an attacker with high privileges and network access to escalate privileges on the host device. Administrators and users of UniFi Access Application should be aware of this vulnerability and take necessary actions to mitigate it.
- Vendor
- Ubiquiti Inc
- Product
- UniFi Access Application
- CVSS
- CRITICAL 9.1
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-07-02
- Original CVE updated
- 2026-07-09
- Advisory published
- 2026-07-02
- Advisory updated
- 2026-07-09
Who should care
Administrators and users of UniFi Access Application should be aware of this vulnerability and take necessary actions to mitigate it. This includes reviewing the supplied official advisory or CVE record to validate affected scope, severity, and vendor guidance. They should also plan vendor-supported updates or mitigations through normal change control where exposure is confirmed.
Technical summary
The vulnerability is caused by an Improper Access Control issue in UniFi Access Application. This allows an attacker with high privileges and network access to escalate privileges on the host device. The CVSS vector for this vulnerability is CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H. The vulnerability has a CVSS score of 9.1 and is categorized as CRITICAL.
Defensive priority
High priority should be given to patching or mitigating this vulnerability as it allows for privilege escalation and has a high CVSS score.
Recommended defensive actions
- Apply the patch or update to version 4.2.29 or later
- Restrict access to the UniFi Access Application
- Monitor for suspicious activity
- Review compensating controls for exposed systems while remediation is scheduled and verified
- Check relevant monitoring, detection, and logs for exposed assets that need extra review
Evidence notes
The CVE record was published on 2026-07-02T15:17:03.623Z and was last modified on 2026-07-09T13:21:25.470Z. The NVD entry is currently Analyzed. The vulnerability is categorized as CRITICAL with a CVSS score of 9.1. Evidence from the CVE record and NVD entry indicates that the vulnerability is caused by an Improper Access Control issue in UniFi Access Application. This allows an attacker with high privileges and network access to escalate privileges on the host device.
Official resources
-
CVE-2026-54400 CVE record
CVE.org
-
CVE-2026-54400 NVD detail
NVD
-
Source item URL
nvd_modified
-
Mitigation or vendor reference
[email protected] - Vendor Advisory
AI-assisted PatchSiren debrief based on the supplied source corpus. The CVE record was published on 2026-07-02T15:17:03.623Z and has not been modified since then. The NVD entry is currently Analyzed.