PatchSiren cyber security CVE debrief
CVE-2026-116837 Ubiquiti Inc CVE debrief
A Heap-based Buffer Overflow vulnerability in airMAX M, LTU, SolarPoint, and SolarSwitch devices could allow a malicious actor with access to the adjacent network to potentially execute arbitrary code on the device. This CVE was published on 2026-10-27T00:44:48.129Z and was last modified on 2026-11-03T20:25:24.601Z. The NVD entry is currently HIGH.
- Vendor
- Ubiquiti Inc
- Product
- airMAX M
- CVSS
- HIGH 8.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-10-27
- Original CVE updated
- 2026-11-03
- Advisory published
- 2026-10-27
- Advisory updated
- 2026-11-03
Who should care
Network administrators and security teams responsible for managing and securing Ubiquiti Inc products airMAX M, LTU, and SolarPoint / SolarSwitch should verify version exposure and potential patching.
Why it matters
CVE-2026-116837 Heap-based Buffer Overflow vulnerability in Ubiquiti Inc products requires verification of version exposure and potential patching to prevent arbitrary code execution.
- Verify version exposure for airMAX M, LTU, and SolarPoint / SolarSwitch
- Potential patching required for affected versions
- Adjacent network access required for exploitation
- Arbitrary code execution potential requires verification
Technical summary
A Heap-based Buffer Overflow vulnerability in airMAX M, LTU, SolarPoint, and SolarSwitch devices could allow a malicious actor with access to the adjacent network to potentially execute arbitrary code on the device. This vulnerability requires verification of version exposure and potential patching to prevent arbitrary code execution. The affected products, including airMAX M, LTU, and SolarPoint / SolarSwitch, need to be assessed for version exposure, and patching should be applied if necessary. The CVE record and source item provide details on the vulnerability,
Defensive priority
Ubiquiti Inc products airMAX M, LTU, and SolarPoint / SolarSwitch require verification of version exposure and potential patching.
Recommended defensive actions
- Verify airMAX M version is 6.3.26 or later
- Verify LTU PTMP version is 2.4.2 or later
- Verify LTU PTP version is 1.5.7 or later
- Verify SolarPoint / SolarSwitch version is 2.0.3 or later
Evidence notes
The CVE record and source item provide details on the vulnerability, affected products, and potential impact. However, verification of version exposure and remediation is required.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-116837 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-116837
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-116837 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-116837
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
CVE-2026-116837
Unverified legacy reference
URL: https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/116xxx/CVE-2026-116837.json
cve_program_cvelist_v5
-
Source reference
Unverified legacy reference
URL: https://uisp.community.ui.com/releases/Security-Advisory-Bulletin-071/7d4d42cf-09e4-44d3-9c19-649cac8c6af3
Supplemental source
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.