PatchSiren cyber security CVE debrief
CVE-2026-6114 Totolink CVE debrief
A vulnerability was detected in Totolink A7100RU 7.4cu.2313_b20191024. The function setNetworkCfg of the file /cgi-bin/cstecgi.cgi of the component CGI Handler is affected by os command injection via the argument proto. The attack may be initiated remotely and a public exploit exists. This vulnerability has a high severity and defenders should assess exposure, especially for remotely accessible devices, and verify current security controls effectiveness. The CVE record and NVD entry provide details, but vendor and affected versions require further verification.
- Vendor
- Totolink
- Product
- A7100RU
- CVSS
- HIGH 8.9
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-04-12
- Original CVE updated
- 2026-10-26
- Advisory published
- 2026-04-12
- Advisory updated
- 2026-10-26
Who should care
Defenders responsible for Totolink A7100RU devices, especially those accessible remotely, should assess exposure and verify the effectiveness of current security controls. This includes reviewing compensating controls for exposed systems while remediation is scheduled and verified, checking relevant monitoring, detection, and logs for exposed assets that need extra review, and tracking exceptions, retesting remediated assets, and closing the item onlyafter
Why it matters
CVE-2026-6114 is a high-severity os command injection vulnerability in Totolink A7100RU devices. Defenders should prioritize verifying exposure, especially for remotely accessible devices, and assess security control effectiveness.
- Verify exposure of Totolink A7100RU devices
- Assess remote attack feasibility
- Monitor public exploit usage for potential attacks
Technical summary
The function setNetworkCfg of the file /cgi-bin/cstecgi.cgi of the component CGI Handler in Totolink A7100RU 7.4cu.2313_b20191024 is vulnerable to os command injection via the argument proto. This vulnerability has a high severity and defenders should assess exposure, especially for remotely accessible devices, and verify current security controls effectiveness. The public exploit existence increases the urgency for defenders to verify exposure and assess security control effectiveness. The CVE record and NVD entry provide details on the vulnerability.
Defensive priority
Defenders should prioritize verifying exposure of Totolink A7100RU devices, especially those accessible remotely, and assess the effectiveness of current security controls.
Recommended defensive actions
- Verify exposure of Totolink A7100RU devices, especially those accessible remotely
- Assess the effectiveness of current security controls
- Monitor for public exploit usage
- Review compensating controls for exposed systems while remediation is scheduled and verified
- Check relevant monitoring, detection, and logs for exposed assets that need extra review
- Track exceptions, retest remediated assets, and close the item only after evidence is documented
- Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up
Evidence notes
The CVE record and NVD entry provide details on the vulnerability. However, the vendor and affected versions require further verification. The vulnerability has a high severity and defenders should assess exposure, especially for remotely accessible devices, and verify current security controls effectiveness. The public exploit existence increases the urgency for defenders to verify exposure and assess security control effectiveness.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-6114 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-6114
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-6114 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-6114
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source reference
Unverified legacy reference
URL: https://github.com/Litengzheng/vuldb_new/blob/main/A7100RU/vul_179/README.md
-
Source reference
Unverified legacy reference
URL: https://vuldb.com/submit/792247
-
Source reference
Unverified legacy reference
URL: https://vuldb.com/vuln/356974
-
Source reference
Unverified legacy reference
URL: https://vuldb.com/vuln/356974/cti
-
Source reference
Unverified legacy reference
URL: https://www.totolink.net/
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.