PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-7057 Tenda CVE debrief

A buffer overflow vulnerability has been identified in Tenda F456 1.0.0.5, specifically in the /goform/setcfm function of the httpd component. This issue allows for remote exploitation through manipulation of the funcname and funcpara1 arguments. The vulnerability has been publicly disclosed and an exploit has been published. Network administrators and IoT security teams should assess their exposure and prioritize patching or implementing compensating controls. The CVE record and NVD detail page provide information on the vulnerability, including its CVSS score of 7.4 and HIGH severity.

Vendor
Tenda
Product
F456
CVSS
HIGH 7.4
CISA KEV
Not listed in stored evidence
Original CVE published
2026-04-26
Original CVE updated
2026-10-26
Advisory published
2026-04-26
Advisory updated
2026-10-26

Who should care

Network administrators, IoT security teams, and organizations using Tenda F456 devices should assess their exposure and prioritize patching or implementing compensating controls. This includes reviewing and applying patches from the vendor, implementing network segmentation and isolation for IoT devices, and monitoring network traffic for suspicious activity.

Why it matters

CVE-2026-7057 is a high-severity buffer overflow vulnerability in Tenda F456 devices that allows for remote exploitation. Network administrators and IoT security teams should prioritize patching or implementing compensating controls to prevent potential attacks.

  • Remote exploitation of the vulnerability
  • Potential for arbitrary code execution or denial of service
  • Need for patching or upgrading affected devices
  • Importance of monitoring network traffic for suspicious activity

Technical summary

The vulnerability is caused by a buffer overflow in the /goform/setcfm function of the httpd component in Tenda F456 1.0.0.5. The funcname and funcpara1 arguments can be manipulated to trigger the overflow, allowing for remote exploitation. This vulnerability has a high CVSS score of 7.4 and is considered HIGH severity. Network administrators and IoT security teams should prioritize patching or implementing compensating controls to prevent potential attacks. The vulnerability allows for potential arbitrary code execution or denial of service.

Defensive priority

High priority for network devices and IoT security

Recommended defensive actions

  • Review and apply patches from the vendor
  • Implement network segmentation and isolation for IoT devices
  • Monitor network traffic for suspicious activity
  • Conduct regular vulnerability assessments and penetration testing
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented

Evidence notes

The CVE record and NVD detail page provide information on the vulnerability, including its CVSS score of 7.4 and HIGH severity. The exploit has been published and may be used. Evidence is limited to public sources and may not reflect the full scope or impact of the vulnerability. Defenders should verify affected scope and vendor guidance.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-7057 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-7057

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-7057 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-7057

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.