PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-67822 Tenda CVE debrief

AI-assisted PatchSiren debrief based on the supplied source corpus. The CVE record was published on 2026-07-31T17:16:35.210Z and has not been modified since then. Tenda W6-S 1.0.0.4(510) contains a stack-based buffer overflow vulnerability in the /goform/wifiSSIDset endpoint. The function formwrlSSIDset uses sprintf to copy user-controlled 'GO' and 'index' parameters into a 64-byte stack buffer without length restriction, leading to stack overflow. Network administrators and security teams should verify and apply vendor patches or updates for Tenda W6-S 1.0.0.4(510) and monitor network traffic for suspicious activity. Limited details available on affected scope and vendor remediation. This vulnerability has a CVSS score of 9.8 and is classified as CRITICAL, indicating a high likelihood of exploitation and potential for significant impact.

Vendor
Tenda
Product
W6‑S
CVSS
CRITICAL 9.8
CISA KEV
Not listed in stored evidence
Original CVE published
2026-07-31
Original CVE updated
2026-08-31
Advisory published
2026-07-31
Advisory updated
2026-08-31

Who should care

Network administrators and security teams responsible for Tenda W6-S 1.0.0.4(510) devices, as well as organizations using vulnerable configurations, should take immediate action to verify and apply vendor patches or updates. This vulnerability has a CVSS score of 9.8 and is classified as CRITICAL, indicating a high likelihood of exploitation and potential for significant impact.

Technical summary

Tenda W6-S 1.0.0.4(510) contains a stack-based buffer overflow vulnerability in the /goform/wifiSSIDset endpoint. The function formwrlSSIDset uses sprintf to copy user-controlled 'GO' and 'index' parameters into a 64-byte stack buffer without length restriction, leading to stack overflow. This vulnerability has a CVSS score of 9.8 and is classified as CRITICAL. Network administrators and security teams should take immediate action to verify and apply vendor patches or updates.

Defensive priority

Critical vulnerability in Tenda W6-S 1.0.0.4(510) with CVSS score of 9.8, requires immediate attention.

Recommended defensive actions

  • Verify and apply vendor patches or updates for Tenda W6-S 1.0.0.4(510)
  • Restrict access to the /goform/wifiSSIDset endpoint
  • Monitor network traffic for suspicious activity
  • Consider implementing compensating controls for vulnerable systems
  • Review and update incident response plans to address potential exploitation
  • Conduct a thorough risk assessment to identify potential vulnerabilities in Tenda W6-S 1.0.0.4(510) deployments
  • Implement additional security measures, such as network segmentation and access controls, to reduce the attack surface

Evidence notes

Evidence from official CVE and NVD sources indicates a stack-based buffer overflow vulnerability in Tenda W6-S 1.0.0.4(510). Limited details available on affected scope and vendor remediation. The function formwrlSSIDset uses sprintf to copy user-controlled 'GO' and 'index' parameters into a 64-byte stack buffer without length restriction, leading to stack overflow. Network administrators and security teams should verify and apply vendor patches or updates for Tenda W6-S 1.0.0.4(510) and monitor network traffic for suspicious activity.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-67822 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-67822

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-67822 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-67822

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.