PatchSiren cyber security CVE debrief
CVE-2026-67822 Tenda CVE debrief
AI-assisted PatchSiren debrief based on the supplied source corpus. The CVE record was published on 2026-07-31T17:16:35.210Z and has not been modified since then. Tenda W6-S 1.0.0.4(510) contains a stack-based buffer overflow vulnerability in the /goform/wifiSSIDset endpoint. The function formwrlSSIDset uses sprintf to copy user-controlled 'GO' and 'index' parameters into a 64-byte stack buffer without length restriction, leading to stack overflow. Network administrators and security teams should verify and apply vendor patches or updates for Tenda W6-S 1.0.0.4(510) and monitor network traffic for suspicious activity. Limited details available on affected scope and vendor remediation. This vulnerability has a CVSS score of 9.8 and is classified as CRITICAL, indicating a high likelihood of exploitation and potential for significant impact.
- Vendor
- Tenda
- Product
- W6‑S
- CVSS
- CRITICAL 9.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-07-31
- Original CVE updated
- 2026-08-31
- Advisory published
- 2026-07-31
- Advisory updated
- 2026-08-31
Who should care
Network administrators and security teams responsible for Tenda W6-S 1.0.0.4(510) devices, as well as organizations using vulnerable configurations, should take immediate action to verify and apply vendor patches or updates. This vulnerability has a CVSS score of 9.8 and is classified as CRITICAL, indicating a high likelihood of exploitation and potential for significant impact.
Technical summary
Tenda W6-S 1.0.0.4(510) contains a stack-based buffer overflow vulnerability in the /goform/wifiSSIDset endpoint. The function formwrlSSIDset uses sprintf to copy user-controlled 'GO' and 'index' parameters into a 64-byte stack buffer without length restriction, leading to stack overflow. This vulnerability has a CVSS score of 9.8 and is classified as CRITICAL. Network administrators and security teams should take immediate action to verify and apply vendor patches or updates.
Defensive priority
Critical vulnerability in Tenda W6-S 1.0.0.4(510) with CVSS score of 9.8, requires immediate attention.
Recommended defensive actions
- Verify and apply vendor patches or updates for Tenda W6-S 1.0.0.4(510)
- Restrict access to the /goform/wifiSSIDset endpoint
- Monitor network traffic for suspicious activity
- Consider implementing compensating controls for vulnerable systems
- Review and update incident response plans to address potential exploitation
- Conduct a thorough risk assessment to identify potential vulnerabilities in Tenda W6-S 1.0.0.4(510) deployments
- Implement additional security measures, such as network segmentation and access controls, to reduce the attack surface
Evidence notes
Evidence from official CVE and NVD sources indicates a stack-based buffer overflow vulnerability in Tenda W6-S 1.0.0.4(510). Limited details available on affected scope and vendor remediation. The function formwrlSSIDset uses sprintf to copy user-controlled 'GO' and 'index' parameters into a 64-byte stack buffer without length restriction, leading to stack overflow. Network administrators and security teams should verify and apply vendor patches or updates for Tenda W6-S 1.0.0.4(510) and monitor network traffic for suspicious activity.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-67822 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-67822
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-67822 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-67822
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source reference
Unverified legacy reference
URL: https://github.com/Tristerjh/Tenda/blob/main/Tenda_W6-S_GO_overflow.md
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.