PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-6200 Tenda CVE debrief

A vulnerability was determined in Tenda F456 1.0.0.5. The affected element is the function formwebtypelibrary of the file /goform/webtypelibrary. This manipulation of the argument menufacturer/Go causes stack-based buffer overflow. The attack can be initiated remotely. This vulnerability has been publicly disclosed and may be utilized. Defenders should assess exposure and prioritize patching or mitigation efforts accordingly. The CVE record and NVD entry provide additional details on the vulnerability.

Vendor
Tenda
Product
F456
CVSS
HIGH 7.4
CISA KEV
Not listed in stored evidence
Original CVE published
2026-04-13
Original CVE updated
2026-10-26
Advisory published
2026-04-13
Advisory updated
2026-10-26

Who should care

Defenders responsible for Tenda F456 devices should assess exposure and potential impact. This includes operators, platform administrators, vulnerability management teams, and security teams who need to prioritize patching or mitigation efforts. The vulnerability has been publicly disclosed and may be utilized, making prompt action essential to minimize potential damage.

Why it matters

Defenders should prioritize verifying exposure of Tenda F456 devices to this vulnerability and assessing the potential impact on their network.

  • Verify exposure of Tenda F456 devices to this vulnerability
  • Assess potential impact on network
  • Monitor for potential exploitation attempts

Technical summary

The vulnerability is caused by a stack-based buffer overflow in the formwebtypelibrary function of the /goform/webtypelibrary file. This can be exploited remotely due to improper input validation. The vulnerability has been publicly disclosed and may be utilized. Defenders should prioritize verifying exposure of Tenda F456 devices to this vulnerability and assessing the potential impact on their network. The CVE record and NVD entry provide additional details on the vulnerability, including its CVSS score and weaknesses.

Defensive priority

Defenders should prioritize verifying exposure of Tenda F456 devices to this vulnerability and assessing the potential impact on their network.

Recommended defensive actions

  • Verify exposure of Tenda F456 devices to this vulnerability
  • Assess the potential impact on the network
  • Monitor for potential exploitation attempts
  • Review vendor guidance for patching or mitigation
  • Conduct a thorough review of network configurations and asset inventory
  • Implement compensating controls for exposed systems while remediation is scheduled and verified
  • Track exceptions and retest remediated assets

Evidence notes

The CVE record and NVD entry provide details on the vulnerability, including its CVSS score and weaknesses (CWE-119 and CWE-121). The vulnerability has been publicly disclosed and may be utilized. Defenders should verify exposure of Tenda F456 devices to this vulnerability and assess the potential impact on their network. The attack can be initiated remotely.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-6200 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-6200

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-6200 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-6200

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.