PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-5830 Tenda CVE debrief

A vulnerability was identified in Tenda AC15 15.03.05.18. This affects the function websGetVar of the file /goform/SysToolChangePwd. Such manipulation of the argument oldPwd/newPwd/cfmPwd leads to stack-based buffer overflow. The attack can be executed remotely. This vulnerability has a high CVSS score of 7.4, indicating high severity. Users of Tenda AC15 15.03.05.18 should assess the vulnerability and apply patches or mitigations as available.

Vendor
Tenda
Product
AC15
CVSS
HIGH 7.4
CISA KEV
Not listed in stored evidence
Original CVE published
2026-04-09
Original CVE updated
2026-07-24
Advisory published
2026-04-09
Advisory updated
2026-07-24

Who should care

Users of Tenda AC15 15.03.05.18 should assess the vulnerability and apply patches or mitigations as available. This includes administrators and security teams responsible for managing and securing network devices. The vulnerability's high CVSS score and remote exploitability make it a high priority for remediation.

Technical summary

The vulnerability affects Tenda AC15 15.03.05.18 and involves the function websGetVar in the file /goform/SysToolChangePwd, leading to a stack-based buffer overflow. The attack can be executed remotely. This vulnerability has a high CVSS score of 7.4, indicating high severity. The exploit is publicly available, which increases the urgency for patching. Users of Tenda AC15 15.03.05.18 should assess the vulnerability and apply patches or mitigations as available. Affected product deployments should be confirmed in managed environments, and owners should be assigned for follow-up. Reviewing the official advisory or CVE record can help validate affected scope, severity, and vendor guidance. Planning vendor-supported updates or mitigations through normal change control is recommended where exposure is confirmed. Compensating controls for exposed systems should be reviewed while remediation is scheduled and verified.

Defensive priority

High priority due to high CVSS score of 7.4 and remote exploitability.

Recommended defensive actions

  • Apply patches or updates provided by Tenda if available.
  • Implement network segmentation and isolation to limit the attack surface.
  • Monitor network traffic for suspicious activity.
  • Consider using a Web Application Firewall (WAF) to detect and prevent attacks.
  • Conduct regular vulnerability assessments and penetration testing.
  • Review compensating controls for exposed systems while remediation is scheduled and verified.
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented.

Evidence notes

The CVE record was published on 2026-04-09T02:16:17.920Z and was last modified on 2026-07-24T09:10:00.153Z. The NVD entry is currently Analyzed. The vulnerability affects Tenda AC15 15.03.05.18 and involves the function websGetVar in the file /goform/SysToolChangePwd, leading to a stack-based buffer overflow. The attack can be executed remotely. Users should verify their deployments and apply patches or mitigations as available.

Official resources

AI-assisted PatchSiren debrief based on the supplied source corpus. The CVE record was published on 2026-04-09T02:16:17.920Z and has not been modified since then. The NVD entry is currently Analyzed.