CVE-2026-5686 Tenda CVE debrief
CVE-2026-5686 is a stack-based buffer overflow vulnerability in Tenda CX12L 16.03.53.12. The vulnerability affects the fromRouteStatic function in /goform/RouteStatic. The manipulation of the argument page results in a stack-based buffer overflow. The attack can be launched remotely. This vulnerability has a high CVSS score of 7.4, indicating a high severity level. Network administrators and security teams responsible for Tenda CX12L devices should prioritize patching this vulnerability to prevent potential remote attacks. The CVE record was published on 2026-04-06T22:16:24.880Z and was last modified on 2026-07-24T09:10:00.153Z.
- Vendor
- Tenda
- Product
- CX12L
- CVSS
- HIGH 7.4
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-04-06
- Original CVE updated
- 2026-07-24
- Advisory published
- 2026-04-06
- Advisory updated
- 2026-07-24
Who should care
Network administrators and security teams responsible for Tenda CX12L devices should prioritize patching this vulnerability to prevent potential remote attacks. The vulnerability affects Tenda CX12L 16.03.53.12, specifically the fromRouteStatic function in /goform/RouteStatic. The manipulation of the argument page results in a stack-based buffer overflow. The attack can be launched remotely. The CVSS score for this vulnerability is 7.4, indicating a high severity level.
Technical summary
The CVE-2026-5686 vulnerability is caused by a stack-based buffer overflow in the fromRouteStatic function of the /goform/RouteStatic file in Tenda CX12L 16.03.53.12. An attacker can exploit this vulnerability remotely by manipulating the argument page. The CVSS score for this vulnerability is 7.4, indicating a high severity level. Network administrators and security teams should prioritize patching this vulnerability to prevent potential remote attacks. The vulnerability affects Tenda CX12L devices, specifically the fromRouteStatic function in /goform/RouteStatic.
Defensive priority
High priority should be given to patching this vulnerability, as it can be exploited remotely and has a high CVSS score.
Recommended defensive actions
- Apply the vendor-provided patch for Tenda CX12L 16.03.53.12
- Limit access to the /goform/RouteStatic endpoint
- Monitor network traffic for suspicious activity
- Perform regular vulnerability scans and updates
- Review compensating controls for exposed systems while remediation is scheduled and verified
- Check relevant monitoring, detection, and logs for exposed assets that need extra review
- Track exceptions, retest remediated assets, and close the item only after evidence is documented
Evidence notes
The CVE record was published on 2026-04-06T22:16:24.880Z and was last modified on 2026-07-24T09:10:00.153Z. The NVD entry is currently Analyzed. The vulnerability affects Tenda CX12L 16.03.53.12, specifically the fromRouteStatic function in /goform/RouteStatic. The manipulation of the argument page results in a stack-based buffer overflow. The attack can be launched remotely. The CVSS score for this vulnerability is 7.4, indicating a high severity level. Network administrators and security teams should prioritize patching this vulnerability to prevent potential remote attacks.
Official resources
-
CVE-2026-5686 CVE record
CVE.org
-
CVE-2026-5686 NVD detail
NVD
-
Source item URL
nvd_modified
-
Mitigation or vendor reference
[email protected] - Exploit, Issue Tracking, Mitigation, Third Party Advisory
-
Mitigation or vendor reference
[email protected] - Third Party Advisory, VDB Entry
-
Mitigation or vendor reference
[email protected] - Third Party Advisory, VDB Entry
-
Source reference
[email protected] - Permissions Required, VDB Entry
-
Source reference
[email protected] - Product
AI-assisted PatchSiren debrief based on the supplied source corpus. The CVE record was published on 2026-04-06T22:16:24.880Z and has not been modified since then. The NVD entry is currently Analyzed.