PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-5684 Tenda CVE debrief

A stack-based buffer overflow vulnerability was determined in Tenda CX12L 16.03.53.12. The issue affects the fromwebExcptypemanFilter function of the file /goform/webExcptypemanFilter. This vulnerability can be exploited through manipulation of the argument page, requiring access to the local network. The CVSS score for this vulnerability is 7.3, classified as HIGH severity. Network administrators and security teams should prioritize patching this vulnerability to prevent potential local network exploitation.

Vendor
Tenda
Product
CX12L
CVSS
HIGH 7.3
CISA KEV
Not listed in stored evidence
Original CVE published
2026-04-06
Original CVE updated
2026-07-24
Advisory published
2026-04-06
Advisory updated
2026-07-24

Who should care

Network administrators and security teams responsible for Tenda CX12L devices should prioritize patching this vulnerability to prevent potential local network exploitation. This includes reviewing the supplied official advisory or CVE record to validate affected scope, severity, and vendor guidance. Compensating controls should be reviewed for exposed systems while remediation is scheduled and verified.

Technical summary

The CVE-2026-5684 vulnerability is a stack-based buffer overflow issue in the fromwebExcptypemanFilter function of Tenda CX12L 16.03.53.12. The vulnerability is triggered by manipulating the argument page in the /goform/webExcptypemanFilter file, and it requires access to the local network for exploitation. The CVSS score for this vulnerability is 7.3, classified as HIGH severity. The vulnerability has been publicly disclosed and may be utilized.

Defensive priority

High priority should be given to patching this vulnerability due to its high severity and the potential for local network exploitation.

Recommended defensive actions

  • Apply the vendor-provided patch for Tenda CX12L 16.03.53.12.
  • Restrict access to the local network to minimize the attack surface.
  • Monitor network traffic for suspicious activity related to the affected function.
  • Review compensating controls for exposed systems while remediation is scheduled and verified.
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review.
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented.
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up.

Evidence notes

The CVE record was published on 2026-04-06T22:16:24.483Z and was last modified on 2026-07-24T09:10:00.153Z. The NVD entry is currently Analyzed. The vulnerability affects Tenda CX12L 16.03.53.12, specifically the fromwebExcptypemanFilter function of the file /goform/webExcptypemanFilter. The issue requires access to the local network for exploitation. The CVSS score for this vulnerability is 7.3, classified as HIGH severity. Evidence limits suggest that further verification is needed to confirm affected scope and severity.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-5684 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-5684

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-5684 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-5684

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.