PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-5609 Tenda CVE debrief

A flaw has been found in Tenda i12 1.0.0.11(3862), specifically in the formwrlSSIDset function of the /goform/wifiSSIDset file. This vulnerability, caused by manipulation of the index/wl_radio argument, leads to a stack-based buffer overflow and allows for remote exploitation. Network administrators and security teams should prioritize patching this vulnerability to prevent potential remote attacks. The CVE record was published on 2026-04-06T02:16:00.670Z and has been analyzed by NVD.

Vendor
Tenda
Product
i12
CVSS
HIGH 7.4
CISA KEV
Not listed in stored evidence
Original CVE published
2026-04-06
Original CVE updated
2026-07-24
Advisory published
2026-04-06
Advisory updated
2026-07-24

Who should care

Network administrators and security teams responsible for Tenda i12 devices should prioritize patching this vulnerability to prevent potential remote attacks. Additionally, security teams should review network traffic for suspicious activity and implement additional security controls such as network segmentation and intrusion detection.

Technical summary

The Tenda i12 1.0.0.11(3862) device contains a stack-based buffer overflow vulnerability in the formwrlSSIDset function of the /goform/wifiSSIDset file. This vulnerability is triggered by manipulation of the index/wl_radio argument and can be exploited remotely, potentially allowing attackers to execute arbitrary code. Affected product deployments should be confirmed in managed environments and assigned an owner for follow-up. Network administrators and security teams should prioritize patching this vulnerability to prevent potential remote attacks. The CVE record was published on 2026-04-06T02:16:00.670Z and has been analyzed by NVD. Evidence of exploitation attempts should be verified through network monitoring and logs.

Defensive priority

High priority should be given to patching this vulnerability due to its high CVSS score of 7.4 and the potential for remote exploitation.

Recommended defensive actions

  • Apply the vendor patch or update to a fixed version if available.
  • Limit access to the /goform/wifiSSIDset endpoint.
  • Monitor network traffic for suspicious activity.
  • Implement additional security controls such as network segmentation and intrusion detection.
  • Review compensating controls for exposed systems while remediation is scheduled and verified.
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented.
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up.

Evidence notes

The CVE record was published on 2026-04-06T02:16:00.670Z and was last modified on 2026-07-24T09:10:00.153Z. The NVD entry is currently Analyzed. The vulnerability affects Tenda i12 1.0.0.11(3862) devices, specifically the formwrlSSIDset function of the /goform/wifiSSIDset file, allowing for remote exploitation due to a stack-based buffer overflow. Evidence of exploitation attempts should be verified through network monitoring and logs.

Official resources

AI-assisted PatchSiren debrief based on the supplied source corpus. The CVE record was published on 2026-04-06T02:16:00.670Z and has not been modified since then. The NVD entry is currently Analyzed.