PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-5605 Tenda CVE debrief

A stack-based buffer overflow vulnerability has been identified in Tenda CH22 1.0.0.1, specifically in the formWrlExtraSet function of the /goform/WrlExtraSet file. The vulnerability can be exploited remotely by manipulating the GO argument, potentially leading to significant damage if left unaddressed. Users of the affected product should apply vendor patches or mitigations as soon as possible. The exploit has been made publicly available, increasing the urgency for patching.

Vendor
Tenda
Product
CH22
CVSS
HIGH 7.4
CISA KEV
Not listed in stored evidence
Original CVE published
2026-04-06
Original CVE updated
2026-07-24
Advisory published
2026-04-06
Advisory updated
2026-07-24

Who should care

Network administrators and security teams responsible for managing Tenda CH22 devices should be aware of this vulnerability and take immediate action to protect their networks. This includes reviewing network configurations, ensuring that all affected devices are identified, and applying vendor patches or mitigations as soon as possible. Additionally, security teams should consider implementing compensating controls and monitoring network traffic for suspicious activity to minimize potential damage.

Technical summary

The CVE-2026-5605 vulnerability is a stack-based buffer overflow in the formWrlExtraSet function of Tenda CH22 1.0.0.1. The vulnerability has a CVSS score of 7.4 and is classified as HIGH severity. The attack vector is network-based, and the vulnerability can be exploited remotely without requiring user interaction. This vulnerability affects Tenda CH22 devices, specifically version 1.0.0.1, and could lead to significant damage if left unaddressed. Users of the affected product should apply vendor patches or mitigations as soon as possible to prevent exploitation.

Defensive priority

High priority should be given to patching or mitigating this vulnerability, as it has been publicly exploited and could lead to significant damage if left unaddressed. Network administrators and security teams should take immediate action to protect their networks, considering compensating controls and monitoring network traffic for suspicious activity.

Recommended defensive actions

  • Apply vendor patches or updates as soon as available
  • Implement network segmentation to limit the attack surface
  • Monitor network traffic for suspicious activity
  • Consider using compensating controls such as Web Application Firewalls (WAFs)
  • Conduct regular vulnerability assessments and penetration testing

Evidence notes

The CVE record was published on 2026-04-06T00:16:19.213Z and last modified on 2026-07-24T09:10:00.153Z. The NVD entry is currently Analyzed. The vulnerability affects Tenda CH22 1.0.0.1 and has a CVSS score of 7.4. The attack vector is network-based, and the vulnerability can be exploited remotely without requiring user interaction. Evidence limits suggest that additional verification is required to confirm affected scope and severity.

Official resources

AI-assisted PatchSiren debrief based on the supplied source corpus. The CVE record was published on 2026-04-06T00:16:19.213Z and has not been modified since then. The NVD entry is currently Analyzed.