PatchSiren cyber security CVE debrief
CVE-2026-4961 Tenda CVE debrief
A vulnerability was identified in Tenda AC6 15.03.05.16. Affected by this vulnerability is the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.
- Vendor
- Tenda
- Product
- AC6
- CVSS
- HIGH 7.4
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-03-27
- Original CVE updated
- 2026-10-26
- Advisory published
- 2026-03-27
- Advisory updated
- 2026-10-26
Who should care
Defenders responsible for Tenda AC6 devices with firmware version 15.03.05.16 should assess exposure and verify the effectiveness of current security controls to prevent remote exploitation.
Why it matters
The CVE-2026-4961 vulnerability in Tenda AC6 devices with firmware version 15.03.05.16 requires verification of exposure and assessment of security controls to prevent remote exploitation.
- Verify exposure of Tenda AC6 devices with firmware version 15.03.05.16
- Assess the effectiveness of current security controls in preventing remote exploitation
- Monitor for publicly available exploits and adjust security controls accordingly
Technical summary
The vulnerability affects the formQuickIndex function in the /goform/QuickIndex file of the Tenda AC6 device with firmware version 15.03.05.16. The manipulation of the PPPOEPassword argument leads to a stack-based buffer overflow, allowing for remote exploitation. Defenders should prioritize verifying exposure of Tenda AC6 devices with firmware version 15.03.05.16 and assessing the effectiveness of current security controls in preventing remote exploitation. The CVE record and NVD entry provide details on the vulnerability, including its description, CVSS score, and affected product information.
Defensive priority
Defenders should prioritize verifying exposure of Tenda AC6 devices with firmware version 15.03.05.16 and assessing the effectiveness of current security controls in preventing remote exploitation.
Recommended defensive actions
- Verify exposure of Tenda AC6 devices with firmware version 15.03.05.16
- Assess the effectiveness of current security controls in preventing remote exploitation
- Monitor for publicly available exploits and adjust security controls accordingly
- Apply vendor patches or updates as available
- Review compensating controls for exposed systems while remediation is scheduled and verified
- Check relevant monitoring, detection, and logs for exposed assets that need extra review
- Track exceptions, retest remediated assets, and close the item only after evidence is documented
Evidence notes
The CVE record and NVD entry provide details on the vulnerability, including its description, CVSS score, and affected product information. However, the corpus does not establish versions, exploitation, impact, or remediation beyond the provided information.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-4961 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-4961
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-4961 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-4961
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source reference
Unverified legacy reference
URL: https://www.tenda.com.cn/
[email protected] - Product
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.