PatchSiren cyber security CVE debrief
CVE-2026-38834 Tenda CVE debrief
CVE-2026-38834 is a command injection vulnerability in Tenda W30E V2.0 V16.01.0.21 via the hostName parameter of the do_ping_action function. This CVE was published on 2026-04-21T17:16:53.257Z and was last modified on 2026-11-11T23:10:00.263Z. The NVD entry is currently Analyzed. Defenders responsible for Tenda W30E devices, particularly those running firmware version 16.01.0.21, should assess exposure and prioritize verification and potential remediation. The vulnerability allows attackers to execute arbitrary commands via a crafted request. The CVSS severity score is HIGH, emphasizing the need for prompt verification and potential remediation.
- Vendor
- Tenda
- Product
- W30E
- CVSS
- HIGH 7.3
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-04-21
- Original CVE updated
- 2026-11-11
- Advisory published
- 2026-04-21
- Advisory updated
- 2026-11-11
Who should care
Defenders responsible for Tenda W30E devices, particularly those running firmware version 16.01.0.21, should assess exposure and prioritize verification and potential remediation.
Why it matters
CVE-2026-38834 is a command injection vulnerability in Tenda W30E V2.0 V16.01.0.21 that allows attackers to execute arbitrary commands. Defenders should prioritize verifying exposure, assessing input validation, and considering remediation due to the HIGH CVSS severity score.
- Defenders must verify exposure of Tenda W30E devices running firmware version 16.01.0.21.
- Input validation and sanitization may be lacking in the do_ping_action function.
- Potential exploitation could lead to arbitrary command execution.
- Remediation priority is high due to the HIGH CVSS severity score.
Technical summary
The Tenda W30E V2.0 V16.01.0.21 device contains a command injection vulnerability in the do_ping_action function via the hostName parameter. This allows attackers to execute arbitrary commands via a crafted request. The vulnerability has a CVSS score of 7.3 and is classified as HIGH severity. Defenders should prioritize verifying exposure of Tenda W30E devices running firmware version 16.01.0.21 and assessing the do_ping_action function's input validation.
Defensive priority
Defenders should prioritize verifying exposure of Tenda W30E devices running firmware version 16.01.0.21 and assessing the do_ping_action function's input validation.
Recommended defensive actions
- Verify Tenda W30E devices running firmware version 16.01.0.21 are exposed to the command injection vulnerability.
- Assess the do_ping_action function's input validation and consider implementing additional validation or sanitization.
- Review network configurations and consider restricting access to the affected function.
- Monitor for potential exploitation attempts and update firmware if available.
Evidence notes
The CVE record and NVD detail page provide information on the vulnerability, including its CVSS score of 7.3 and severity of HIGH. The do_ping_action function is vulnerable to command injection via the hostName parameter.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-38834 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-38834
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-38834 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-38834
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source reference
Unverified legacy reference
URL: https://github.com/jsjbcyber/repo/blob/main/rep_1.md
[email protected] - Exploit, Third Party Advisory
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.