PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-35555 Subnet Solutions CVE debrief

CVE-2026-35555 is an access-control issue in Subnet Solutions PowerSYSTEM Center’s device project groups feature. According to the CISA CSAF advisory, an authenticated user with limited permissions can perform an unauthorized deletion of project groups. The supplied CVSS 3.1 vector indicates low-privilege, no-user-interaction impact centered on integrity.

Vendor
Subnet Solutions
Product
PowerSYSTEM Center 2020
CVSS
MEDIUM 6.3
CISA KEV
Not listed in stored evidence
Original CVE published
2026-05-12
Original CVE updated
2026-05-12
Advisory published
2026-05-12
Advisory updated
2026-05-12

Who should care

OT and industrial-control-system administrators, PowerSYSTEM Center operators, system integrators, and security teams responsible for account and role management should review this advisory. Organizations running the affected PowerSYSTEM Center product lines should prioritize remediation, especially where project-group permissions are delegated to non-administrative users.

Technical summary

The advisory describes an authorization weakness in the PowerSYSTEM Center feature for device project groups. A limited authenticated user can delete project groups without being authorized to do so. The supplied CVSS vector is AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L, indicating adjacent-network reachability, low attack complexity, low privileges required, no user interaction, high integrity impact, and low availability impact. CISA’s CSAF record also marks the SSVC outcome as E:N/A:N.

Defensive priority

Medium-High: prioritize prompt patching because the issue directly affects authorization and can allow destructive changes by a low-privilege authenticated user.

Recommended defensive actions

  • Update to the vendor-fixed releases listed in the advisory: PSC 2020 Update 29, PSC 2024 Update 2, or PSC 2026 GA Hotfix, as applicable to your deployment.
  • Review user activity records to confirm users are following acceptable usage policies and to detect unauthorized project-group changes.
  • If upgrade assistance is needed, contact Subnet Solutions support or a Subnet Solutions System Integration team member using the contact information in the advisory.

Evidence notes

All claims are drawn from the supplied CISA CSAF advisory for ICSA-26-132-02/CVE-2026-35555 and the linked official CVE record. The corpus lists the issue as publicly disclosed on 2026-05-12, with no KEV entry and no threat/known-ransomware information provided. The advisory’s remediation guidance is limited to vendor-fixed releases and monitoring user activity records.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-35555 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-35555

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-35555 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-35555

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source item URL

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-132-02.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-132-02

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ncas/tips/ST04-014

    Reference

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.