PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-131175 Splunk CVE debrief

A SPL injection vulnerability exists in Splunk Enterprise versions below 10.4.4, 10.2.8, 10.0.11, and 9.4.16. An attacker with the 'power' Splunk role can create a malicious metric alert that, when opened by another authenticated user, can run arbitrary SPL, potentially exposing, modifying data, or disrupting services. The vulnerability requires user interaction, as the attacker must trick the user into opening a link. The user who holds the 'power' Splunk role should not be able to exploit the vulnerability at will. To address this, defenders should prioritize patching vulnerable Splunk Enterprise instances, especially those with users holding the 'power' role, and monitor for [c

Vendor
Splunk
Product
Splunk Enterprise
CVSS
HIGH 7.6
CISA KEV
Not listed in stored evidence
Original CVE published
2026-11-19
Original CVE updated
2026-11-20
Advisory published
2026-11-19
Advisory updated
2026-11-20

Who should care

Splunk Enterprise administrators and users with the 'power' Splunk role should assess their exposure and take steps to mitigate the vulnerability. This includes reviewing their current Splunk Enterprise versions, identifying users with the 'power' role, and implementing necessary patches or compensating controls. Additionally, they should educate users on the risks of opening links from untrusted sources and monitor for suspicious metric alert activity.

Why it matters

Defenders should prioritize patching vulnerable Splunk Enterprise instances, especially those with users holding the 'power' role, and monitor for suspicious metric alert activity. The vulnerability requires user interaction, but can have significant consequences if exploited.

  • Potential data exposure or modification
  • Possible disruption of services available in the affected session
  • Need for verification of affected versions and remediation status
  • Requirement for monitoring and incident response planning

Technical summary

The vulnerability exists because Analytics Workspace does not fully neutralize metric alert names before including them in SPL. An attacker with the 'power' Splunk role can create a malicious metric alert that, when opened by another authenticated user, can run arbitrary SPL. This can lead to potential data exposure or modification, disruption of services available in the affected session, and requires verification of affected versions and remediation status. The vulnerability requires the attacker to phish the user by tricking them into opening a link that the attacker creates.

Defensive priority

Defenders should prioritize patching vulnerable Splunk Enterprise instances, especially those with users holding the 'power' role, and monitor for suspicious metric alert activity.

Recommended defensive actions

  • Patch Splunk Enterprise instances to versions 10.4.4, 10.2.8, 10.0.11, or 9.4.16
  • Monitor for suspicious metric alert activity
  • Restrict the 'power' Splunk role to only necessary users
  • Educate users on the risks of opening links from untrusted sources
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented

Evidence notes

The vulnerability requires the attacker to phish the user by tricking them into opening a link that the attacker creates. The user who holds the 'power' Splunk role should not be able to exploit the vulnerability at will.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-131175 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-131175

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-131175 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-131175

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.