PatchSiren cyber security CVE debrief
CVE-2026-4149 Sonos CVE debrief
A critical vulnerability exists in Sonos Era 300 devices, allowing remote code execution without authentication. The flaw is within the handling of the DataOffset field in SMB responses, caused by improper validation of user-supplied data. This can lead to a memory access past the end of an allocated buffer, enabling attackers to execute code in the kernel context.
- Vendor
- Sonos
- Product
- Era 300
- CVSS
- CRITICAL 9.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-04-11
- Original CVE updated
- 2026-10-26
- Advisory published
- 2026-04-11
- Advisory updated
- 2026-10-26
Who should care
IT administrators responsible for Sonos Era 300 devices, network administrators, and cybersecurity teams should assess exposure and apply remediation to prevent potential remote code execution.
Why it matters
CVE-2026-4149 is a critical vulnerability in Sonos Era 300 devices that allows remote code execution without authentication. It exists within the handling of SMB responses and can be exploited to execute code in the kernel context. Immediate attention is required to assess exposure and apply remediation.
- Remote code execution in the kernel context
- Potential for unauthorized access and control
- Need for immediate firmware updates
- Requirement for network monitoring and access controls
Technical summary
The vulnerability exists within the handling of the DataOffset field in SMB responses. Lack of proper validation of user-supplied data can result in a memory access past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the kernel. This critical vulnerability in Sonos Era 300 devices allows remote code execution without authentication and exists within the handling of SMB responses. It can be exploited to execute code in the kernel context. Immediate attention is required to assess exposure and apply remediation to prevent potential remote code execution.
Defensive priority
Immediate attention is required to assess exposure and apply remediation to prevent potential remote code execution.
Recommended defensive actions
- Assess exposure of Sonos Era 300 devices in the environment
- Verify firmware versions and apply updates if available
- Implement network monitoring to detect potential exploitation attempts
- Restrict SMB access to trusted sources
- Review compensating controls for exposed systems while remediation is scheduled and verified
- Track exceptions, retest remediated assets, and close the item only after evidence is documented
- Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up
Evidence notes
The vulnerability is confirmed to exist in Sonos Era 300 devices with firmware versions prior to 83.1-61240. The issue is related to the handling of SMB responses and can be exploited without authentication.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-4149 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-4149
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-4149 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-4149
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source reference
Unverified legacy reference
URL: https://www.zerodayinitiative.com/advisories/ZDI-26-192/
[email protected] - Third Party Advisory
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.