PatchSiren cyber security CVE debrief
CVE-2025-5485 SinoTrack CVE debrief
CVE-2025-5485 affects SinoTrack’s IOT PC Platform and related GPS receiver management access. CISA says the web management interface uses a numerical device identifier as the username, capped at 10 digits, which allows a malicious actor to enumerate likely targets by incrementing or decrementing known identifiers or by trying random digit sequences. The advisory rates the issue HIGH and lists all versions of the affected product family.
- Vendor
- SinoTrack
- Product
- IOT PC Platform
- CVSS
- HIGH 8.6
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-06-10
- Original CVE updated
- 2025-06-10
- Advisory published
- 2025-06-10
- Advisory updated
- 2025-06-10
Who should care
Organizations using SinoTrack IOT PC Platform or SinoTrack GPS receiver deployments should pay attention, especially teams that administer the web management interface, operate exposed fleet-management systems, or publish device photos/labels that could reveal identifiers.
Technical summary
The advisory describes an information disclosure / account-enumeration weakness in the web management interface: usernames are constrained to the device identifier, a numeric value up to 10 digits. That makes valid target discovery easier because identifiers can be guessed from nearby values or by sampling digit sequences. CISA’s supplied CVSS v3.1 vector is AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L (8.6 HIGH).
Defensive priority
High. Prioritize if the management interface is reachable beyond a trusted admin network or if device identifiers are visible in public photos or other externally accessible materials.
Recommended defensive actions
- Change any default password to a unique, complex password as soon as practical in the management interface.
- Conceal the device identifier; remove or replace public photographs that expose the sticker or label if needed.
- Restrict access to the web management interface to trusted administrative networks or other tightly controlled paths.
- Inventory affected SinoTrack devices and treat the advisory as applicable to all versions listed in the CSAF notice.
- Follow CISA ICS recommended practices and broader ICS hardening guidance referenced in the advisory.
- Contact SinoTrack through the vendor help center for product-specific guidance and updates.
Evidence notes
Based on CISA advisory ICSA-25-160-01 (published and modified 2025-06-10), which states that usernames for the web management interface are limited to the device identifier and can be enumerated by an attacker. The CSAF lists SinoTrack IOT PC Platform vers:all/* as affected, includes mitigation guidance to change the default password and conceal the device identifier, and notes that SinoTrack did not respond to CISA’s coordination request.
Sources and references
Verified primary and authoritative sources
-
CVE-2025-5485 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2025-5485
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2025-5485 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2025-5485
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-160-01.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-160-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ncas/tips/ST04-014
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.