PatchSiren cyber security CVE debrief
CVE-2026-47154 Silicon Labs CVE debrief
A vulnerability in EmberZNet v9.0.2 and earlier allows a malformed GetProfileResponse message to trigger out-of-bounds reads, potentially terminating the process. This issue affects devices supporting the Simple Metering cluster that have joined the network. The vulnerability can cause significant disruptions to network operations and defenders should prioritize verifying network configurations and updating vulnerable devices. The CVE record and NVD entry provide details on the vulnerability, but additional information on affected devices and remediation steps is limited.
- Vendor
- Silicon Labs
- Product
- EmberZNet
- CVSS
- HIGH 7.1
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-06-25
- Original CVE updated
- 2026-10-25
- Advisory published
- 2026-06-25
- Advisory updated
- 2026-10-25
Who should care
Defenders responsible for network configurations and device management should assess exposure and prioritize updates for devices supporting the Simple Metering cluster. They should also review official advisories, plan for vendor-supported updates or mitigations, and monitor network activity for potential attacks. Security teams should track exceptions, retest remediated assets, and verify evidence of remediation.
Why it matters
CVE-2026-47154 is a high-severity vulnerability in EmberZNet v9.0.2 and earlier that can cause out-of-bounds reads and process termination. Defenders should prioritize verifying network configurations, updating vulnerable devices, and monitoring network activity.
- Verification of network configurations is necessary to identify potentially vulnerable devices.
- Updating vulnerable devices is crucial to prevent potential process termination.
- Monitoring network activity for malformed GetProfileResponse messages can help detect potential attacks.
Technical summary
The vulnerability is triggered by a malformed GetProfileResponse message, which can cause out-of-bounds reads and potentially terminate the process. This issue affects devices that support the Simple Metering cluster and have joined the network. The vulnerability can cause significant disruptions to network operations and defenders should prioritize verifying network configurations and updating vulnerable devices. The CVE record and NVD entry provide details on the vulnerability, but additional information on affected devices and remediation steps is limited.
Defensive priority
Defenders should prioritize verifying network configurations and updating vulnerable devices.
Recommended defensive actions
- Verify network configurations to identify potentially vulnerable devices.
- Update devices supporting the Simple Metering cluster to a version beyond 9.0.2 if available.
- Monitor network activity for malformed GetProfileResponse messages.
- Review compensating controls for exposed systems while remediation is scheduled and verified.
- Check relevant monitoring, detection, and logs for exposed assets that need extra review.
- Track exceptions, retest remediated assets, and close the item only after evidence is documented.
- Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up.
Evidence notes
The CVE record and NVD entry provide details on the vulnerability, but additional information on affected devices and remediation steps is limited. Defenders should verify network configurations, review official advisories, and plan for vendor-supported updates or mitigations. The vulnerability affects devices supporting the Simple Metering cluster and have joined the network. There is no information on public exploitation or specific attacks.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-47154 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-47154
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-47154 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-47154
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source reference
Unverified legacy reference
URL: https://github.com/SiliconLabsSoftware/sisdk-release/
[email protected] - Not Applicable
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.