CVE-2026-25656 Siemens CVE debrief
CVE-2026-25656 is a high-severity local privilege-escalation issue affecting Siemens SINEC NMS and the User Management Component (UMC). According to the CISA-republished Siemens advisory, a low-privileged user can improperly modify a configuration file, which may allow malicious DLL loading and potentially lead to arbitrary code execution with SYSTEM privileges. Siemens has issued fixed versions for the affected product lines, and defenders should prioritize patching on hosts where local users or service accounts are present.
- Vendor
- Siemens
- Product
- SINEC NMS
- CVSS
- HIGH 7.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-02-10
- Original CVE updated
- 2026-04-16
- Advisory published
- 2026-02-10
- Advisory updated
- 2026-04-16
Who should care
Administrators and security teams responsible for Siemens SINEC NMS and UMC deployments, especially on Windows systems that allow local logons, shared administration, or low-privileged user access.
Technical summary
The published advisory describes a configuration-file integrity weakness that can be abused by a low-privileged local user. The stated outcome is malicious DLL loading and possible code execution with SYSTEM privileges. The supplied CVSS v3.1 vector is AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H, consistent with a local attack that can materially affect confidentiality, integrity, and availability once exploitation conditions are met.
Defensive priority
High; prioritize patching on any exposed SINEC NMS or UMC system where local user access exists.
Recommended defensive actions
- Update Siemens SINEC NMS to V2.15.2.1 or later, or to V4.0 SP3 or later, depending on the installed product line.
- Restrict low-privileged local access on affected hosts until remediation is complete.
- Review permissions on application configuration files and related directories to ensure standard users cannot modify them.
- Monitor affected systems for unexpected DLL loading behavior and unauthorized changes to application configuration files.
- Follow CISA ICS recommended practices and defense-in-depth guidance for industrial control environments.
Evidence notes
The source corpus is a CISA CSAF republication of Siemens ProductCERT advisory SSA-311973 for ICSA-26-043-01, published 2026-02-10 and updated through 2026-04-16. The description, product names, and remediations are taken from the supplied advisory metadata. The enrichment marks this as not listed in CISA KEV. No exploit code or offensive instructions are included.
Official resources
-
CVE-2026-25656 CVE record
CVE.org
-
CVE-2026-25656 NVD detail
NVD
-
Source item URL
cisa_csaf
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
CISA published the advisory on 2026-02-10 and republished updates through 2026-04-16 based on Siemens ProductCERT SSA-311973. In the supplied enrichment, this CVE is not listed in CISA KEV.