A vulnerability has been identified in multiple Siemens products, including APOGEE MBC (PPC) (BACnet), APOGEE MBC (PPC) (P2 Ethernet), APOGEE MEC (PPC) (BACnet), APOGEE MEC (PPC) (P2 Ethernet), APOGEE PXC Compact (BACnet), APOGEE PXC Compact (P2 Ethernet), APOGEE PXC Modular (BACnet), APOGEE PXC Modular (P2 Ethernet), TALON TC Compact (BACnet), and TALON TC Modular (BACnet). The affected product web service does not properly validate the length of user-controllable input, allowing an unauthenticated remote attacker to read portions of device memory or cause a denial-of-service condition.
- Vendor
- Siemens
- Product
- APOGEE MBC (PPC) (BACnet)
- CVSS
- HIGH 8.2
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-10-13
- Original CVE updated
- 2026-10-13
- Advisory published
- 2026-10-13
- Advisory updated
- 2026-10-13
Who should care
Defenders responsible for Siemens products, especially those exposed to the internet or untrusted networks, should assess exposure and prioritize patching or mitigation. This includes operators of affected systems, platform administrators, vulnerability management teams, and security teams responsible for reviewing and implementing mitigations.
Why it matters
CVE-2026-102073 is a high-severity vulnerability in multiple Siemens products, allowing unauthenticated remote attackers to read device memory or cause a denial-of-service condition. Defenders should prioritize patching or mitigation, especially in exposed systems.
- Read portions of device memory
- Denial-of-service condition possible
- Verify patching or mitigation priority
- Assess exposure in internet-exposed systems
Technical summary
The affected Siemens products do not properly validate user-controllable input, allowing an unauthenticated remote attacker to read portions of device memory or cause a denial-of-service condition. This vulnerability affects multiple Siemens products, including APOGEE MBC (PPC) (BACnet), APOGEE MBC (PPC) (P2 Ethernet), APOGEE MEC (PPC) (BACnet), APOGEE MEC (PPC) (P2 Ethernet), APOGEE PXC Compact (BACnet), APOGEE PXC Compact (P2 Ethernet), APOGEE PXC Modular (BACnet), APOGEE PXC Modular (P2 Ethernet), TALON TC Compact (BACnet), and TALON TC Modular (BACnet).
Defensive priority
Defenders should prioritize patching or mitigating this vulnerability, especially in systems exposed to the internet or untrusted networks.
Recommended defensive actions
- Patch or update affected Siemens products to the latest version.
- Implement network segmentation or access controls to limit exposure.
- Monitor system logs for suspicious activity.
- Verify system configurations and inventory for affected products.
- Review compensating controls for exposed systems while remediation is scheduled and verified.
- Check relevant monitoring, detection, and logs for exposed assets that need extra review.
- Track exceptions, retest remediated assets, and close the item only after evidence is documented.
Evidence notes
The CVE record and Siemens advisory provide details on the affected products and versions. However, the corpus does not establish specific exploitation or impact instances. Defenders should verify patching or mitigation priority based on exposed systems and review system configurations and inventory for affected products. Limited evidence is available on actual exploitation or specific impacts.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-102073 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-102073
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-102073 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-102073
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
CVE-2026-102073
Unverified legacy reference
URL: https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/102xxx/CVE-2026-102073.json
cve_program_cvelist_v5
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-333035.html
Supplemental source
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.