CVE-2025-6052 is a low-severity memory-handling flaw described in CISA’s ICSA-26-134-10 advisory and republished from Siemens ProductCERT SSA-032379. The issue is a size-calculation overflow in GLib’s GString logic when appending data to already large strings, which can lead to an undersized allocation and out-of-bounds writes. The supplied advisory maps the issue to Siemens SIMATIC CN 4100 versions earlier than V5.0, and Siemens lists V5.0 or later as the fix.
- Vendor
- Siemens
- Product
- SIMATIC CN 4100
- CVSS
- LOW 3.7
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-05-12
- Original CVE updated
- 2026-05-14
- Advisory published
- 2026-05-12
- Advisory updated
- 2026-05-14
Who should care
Asset owners, OT administrators, and patch-management teams responsible for Siemens SIMATIC CN 4100 devices should care, especially if they operate versions earlier than V5.0. Security teams should also review whether any embedded software in their environment includes the affected GLib component. Because the supplied vendor mapping is low confidence, inventory validation is important before prioritizing remediation.
Technical summary
The advisory describes an integer-overflow-style flaw in the GString memory-growth path: when a string is already very large, adding more data can overflow the internal size calculation. If the computed size wraps, the code may believe the allocation is sufficient when it is not, creating a path to writing past the end of allocated memory. The supplied CVSS vector (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L) indicates network reachability, high attack complexity, no privileges, no user interaction, and limited availability impact. The source metadata ties this to Siemens SIMATIC CN 4100 versions before V5.0, but that product attribution is marked low confidence in the supplied data.
Defensive priority
Routine patch priority, with higher urgency if the affected Siemens product is present in operational or safety-critical environments. The severity is low and the supplied data does not indicate KEV inclusion, but a vendor fix is available and memory corruption in OT-adjacent systems can still create reliability risk.
Recommended defensive actions
- Verify whether Siemens SIMATIC CN 4100 devices or related components are deployed in your environment.
- If affected versions are present, update to Siemens V5.0 or later as recommended in the advisory.
- Cross-check the vendor/product mapping against Siemens ProductCERT SSA-032379 before scheduling remediation, because the supplied vendor attribution is marked low confidence.
- If immediate patching is not possible, limit management access to the device and monitor for crashes, restarts, or other stability issues.
- Track CISA ICSA-26-134-10 and Siemens advisory updates for any revision changes or follow-on guidance.
Evidence notes
All substantive claims here are drawn from the supplied CISA CSAF source item for ICSA-26-134-10 and its referenced Siemens ProductCERT advisory. The source describes a GLib GString size-calculation overflow that can cause memory corruption or crashes, and it lists remediation as upgrading to V5.0 or later. The supplied metadata also includes the CVSS vector CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L and marks the vendor/product attribution as low confidence and needing review. Timeline context uses the provided publication and modification dates only: 2026-05-12 and 2026-05-14.
Sources and references
Verified primary and authoritative sources
-
CVE-2025-6052 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2025-6052
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2025-6052 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2025-6052
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-134-10.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-032379.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-032379.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-134-10
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.