CVE-2025-4615 is a medium-severity issue described in the CISA/Siemens advisory corpus for Siemens RUGGEDCOM APE1808. The source set says an authenticated administrator could bypass system restrictions and execute arbitrary commands, but it also contains a conflicting PAN-OS product description, so responders should validate the affected asset and rely on the Siemens/CISA advisory references. Prioritize administrator access controls and vendor-provided updates.

Vendor
Siemens
Product
RUGGEDCOM APE1808
CVSS
MEDIUM 6.5
CISA KEV
Not listed in stored evidence
Original CVE published
2025-06-10
Original CVE updated
2026-03-12
Advisory published
2025-06-10
Advisory updated
2026-03-12

Who should care

OT/ICS owners and administrators of Siemens RUGGEDCOM APE1808, security teams responsible for privileged access management, and incident responders validating management-interface exposure.

Technical summary

The advisory corpus describes an improper input neutralization issue in a management web interface that can let an authenticated administrator bypass restrictions and execute arbitrary commands. The supplied CVSS vector is CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H, which reflects network reachability but a high privilege requirement. The source material also includes a product-description inconsistency: the advisory metadata names Siemens RUGGEDCOM APE1808, while the vulnerability text references Palo Alto Networks PAN-OS.

Defensive priority

Medium

Recommended defensive actions

  • Restrict CLI and administrative access to a limited, approved group of administrators.
  • Contact Siemens customer support to obtain patch and update guidance for RUGGEDCOM APE1808.
  • Confirm whether any exposed management web interfaces map to the affected product and isolate them if needed.
  • Review privileged account usage and management-interface logs for unexpected administrative activity.
  • Apply OT network segmentation and CISA-recommended industrial control system defensive practices around management-plane access.

Evidence notes

The source corpus identifies CISA advisory ICSA-25-162-02 for Siemens RUGGEDCOM APE1808 and includes remediations to restrict CLI access and contact customer support for patch/update information. The same corpus also contains a conflicting description that names Palo Alto Networks PAN-OS, which should be treated as a source-data inconsistency rather than an additional confirmed affected product. Published date is 2025-06-10 and the latest modified date in the supplied timeline is 2026-03-12.

Sources and references

Verified primary and authoritative sources

  • CVE-2025-4615 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2025-4615

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2025-4615 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2025-4615

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source item URL

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-162-02.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/csaf/ssa-513708.json

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/html/ssa-513708.html

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-162-02

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf

    Reference

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.