PatchSiren cyber security CVE debrief
CVE-2025-40940 Siemens CVE debrief
CVE-2025-40940 is a Siemens SIMATIC CN 4100 issue described by CISA as inconsistent SNMP behavior across protocol versions, including unexpected service availability and unreliable configuration handling. The reported impact is potential access to sensitive data, which can lead to a confidentiality breach. Siemens' listed remediation is to update to V4.0.1 or later.
- Vendor
- Siemens
- Product
- SIMATIC CN 4100
- CVSS
- MEDIUM 4.9
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-12-09
- Original CVE updated
- 2025-12-09
- Advisory published
- 2025-12-09
- Advisory updated
- 2025-12-09
Who should care
Siemens SIMATIC CN 4100 operators, OT/ICS administrators, and security teams responsible for devices with SNMP enabled should review this issue and verify whether the affected product is present in their environment.
Technical summary
The supplied advisory text says the affected application can behave inconsistently when handling SNMP across protocol versions, with unexpected service availability and unreliable configuration handling. CISA's CSAF record assigns CVSS 3.1 vector AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N, indicating a network-reachable issue that requires high privileges and primarily impacts confidentiality. No integrity or availability impact is stated in the corpus. The only explicit vendor remediation provided is to update to V4.0.1 or later.
Defensive priority
Medium. Plan remediation in the next maintenance window or sooner for any SIMATIC CN 4100 deployment where SNMP is enabled or management access is broadly reachable.
Recommended defensive actions
- Apply the Siemens fix and update SIMATIC CN 4100 to V4.0.1 or later.
- Confirm whether SNMP is enabled on affected devices and restrict access to trusted administrative networks.
- Review post-update device behavior to confirm SNMP configuration handling is stable across supported protocol versions.
- Use CISA ICS recommended practices and defense-in-depth guidance to reduce exposure of management interfaces.
- Monitor OT/ICS management paths for unauthorized access attempts against SNMP-enabled services.
Evidence notes
This debrief is based only on the supplied CISA CSAF advisory metadata for ICSA-26-015-12 / CVE-2025-40940 and its cited Siemens references. The corpus explicitly states inconsistent SNMP behavior, unexpected service availability, unreliable configuration handling, and possible access to sensitive data, with remediation to update to V4.0.1 or later. No exploit code, proof-of-concept, active exploitation status, or KEV listing is present in the supplied sources.
Sources and references
Verified primary and authoritative sources
-
CVE-2025-40940 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2025-40940
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2025-40940 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2025-40940
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-015-12.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-416652.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-416652.html
Reference
-
Source reference
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-26-015-12.json
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-12
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference