CVE-2025-39812 is documented in a CISA-republished Siemens advisory as an uninitialized-field issue in Linux kernel SCTP IPv6 handling. The reported bug leaves sin6_scope_id and sin6_flowinfo insufficiently initialized in sctp_v6_from_sk(), which can trigger undefined behavior and KMSAN uninit-value reports during SCTP address comparison and listen-path processing. The source corpus ties the advisory to Siemens SIMATIC CN 4100, but the vulnerability description itself is for the Linux kernel, so applicability should be verified before acting.

Vendor
Siemens
Product
SIMATIC CN 4100
CVSS
MEDIUM 5.5
CISA KEV
Not listed in stored evidence
Original CVE published
2026-05-12
Original CVE updated
2026-05-14
Advisory published
2026-05-12
Advisory updated
2026-05-14

Who should care

Teams responsible for Siemens SIMATIC CN 4100 deployments, as well as administrators or engineers tracking Linux kernel SCTP behavior on affected systems, should review this advisory. Because the source corpus contains a product-description mismatch, asset owners should confirm whether the advisory applies to their environment before prioritizing remediation.

Technical summary

The advisory text says sctp_v6_from_sk() did not properly initialize sin6_scope_id and sin6_flowinfo. That can propagate uninitialized data into SCTP IPv6 address comparison logic, where the supplied KMSAN trace shows __sctp_v6_cmp_addr(), sctp_inet6_cmp_addr(), and related bind/listen paths observing an uninitialized value. The remediation listed in the source corpus is to update to V5.0 or later. The advisory metadata, however, associates this CVE with Siemens SIMATIC CN 4100 while the description is clearly a Linux kernel SCTP fix, so the product scope should be validated against the vendor advisory.

Defensive priority

Medium

Recommended defensive actions

  • Verify whether your asset inventory includes Siemens SIMATIC CN 4100 systems referenced by SSA-032379 / ICSA-26-134-10.
  • If the advisory applies, update to V5.0 or later as stated in the Siemens remediation.
  • Check the Siemens ProductCERT and CISA advisory pages to confirm product scope and affected versions before making changes.
  • Review systems for SCTP-related stability or memory-safety findings consistent with uninitialized-value behavior.
  • Treat the advisory mapping as low-confidence until the Linux-kernel description and Siemens product identification are reconciled.

Evidence notes

Timing context: the CISA source item and CVE record were published on 2026-05-12 and modified on 2026-05-14; the 2026-05-14 update reflects republication of Siemens ProductCERT SSA-032379 material. The source corpus explicitly states the Linux kernel SCTP fix: initialize more fields in sctp_v6_from_sk(), clear sin6_scope_id and sin6_flowinfo, and KMSAN observed an uninit-value in __sctp_v6_cmp_addr() and related SCTP listen/bind paths. At the same time, the advisory metadata identifies the product as Siemens SIMATIC CN 4100 vers:intdot/<5.0, creating a product-mapping inconsistency that warrants manual review. The provided CVSS vector is CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H, which supports a medium severity rating focused on availability.

Sources and references

Verified primary and authoritative sources

  • CVE-2025-39812 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2025-39812

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2025-39812 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2025-39812

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source item URL

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-134-10.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/csaf/ssa-032379.json

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/html/ssa-032379.html

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-134-10

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf

    Reference

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.