PatchSiren cyber security CVE debrief
CVE-2025-39715 Siemens CVE debrief
CVE-2025-39715 is described in the supplied advisory corpus as a Linux kernel PARISC gateway LWS access-check flaw, republished by CISA in Siemens advisory ICSA-26-134-10. The source says the gateway path used load/stbys,e instructions to detect memory-reference interruptions, but those read-access interruptions are only triggered at privilege levels 2 and 3. Because the kernel and gateway page execute at privilege level 0, the check could be bypassed and user code could reach an LWS compare-and-swap operation at an address that should be read-protected at privilege level 3. Siemens maps the issue to SIMATIC CN 4100 versions below 5.0 and recommends updating to V5.0 or later.
- Vendor
- Siemens
- Product
- SIMATIC CN 4100
- CVSS
- MEDIUM 5.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-05-12
- Original CVE updated
- 2026-05-14
- Advisory published
- 2026-05-12
- Advisory updated
- 2026-05-14
Who should care
Administrators responsible for Siemens SIMATIC CN 4100 deployments and teams maintaining affected Linux kernel/PARISC-based systems should review this issue, especially where local users or services can execute code on the device. The product mapping in the corpus is low-confidence and should be validated against Siemens advisory materials before actioning fleet-wide changes.
Technical summary
The vulnerability is a local-access control issue in the parisc gateway LWS call path. According to the source, the kernel attempted to rely on memory-reference interruptions from load/stbys,e instructions to enforce read access, but those interruptions do not occur when the code runs at privilege level 0. As a result, the access check did not correctly detect read-protected user addresses. The fix is to probe read access rights at privilege level 3 and branch to lws_fault when access is not allowed. The supplied CVSS vector is CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H, which corresponds to a medium-severity issue with local attack prerequisites and high availability impact.
Defensive priority
Medium — prioritize normal patch cycles for affected Siemens assets, with higher urgency if the system is exposed to local user execution or is operationally sensitive.
Recommended defensive actions
- Update affected Siemens SIMATIC CN 4100 systems to V5.0 or later, as directed in the supplier remediation.
- Verify whether the Siemens product mapping applies to your environment, since the source description is a Linux kernel PARISC fix note republished in an ICS advisory.
- Use the linked CISA and Siemens advisory pages to confirm affected versions, deployment scope, and any vendor-specific operational guidance before scheduling maintenance.
Evidence notes
Dates and severity are taken from the supplied timeline and source item: published 2026-05-12 and modified 2026-05-14. The corpus ties the CVE to CISA advisory ICSA-26-134-10, republished from Siemens ProductCERT SSA-032379, and includes a remediation to update to version V5.0 or later. The description text itself is a Linux kernel PARISC gateway access-check explanation; the Siemens product association in the corpus is therefore treated as low-confidence and should be reviewed. No KEV listing was provided in the source data.
Sources and references
Verified primary and authoritative sources
-
CVE-2025-39715 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2025-39715
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2025-39715 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2025-39715
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-134-10.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-032379.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-032379.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-134-10
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.