CVE-2025-39694 Siemens CVE debrief

CVE-2025-39694 is a high-severity vulnerability described in the Linux kernel s390/sclp tracing path: a NULL SCCB address is checked after physical-to-virtual translation, which can cause the check to fail when the kernel identity mapping does not start at zero. The result may be incorrect access to the first page of the identity mapping. The supplied advisory set was published by CISA on 2026-05-12 and republished on 2026-05-14. The source corpus also links the CVE to Siemens SIMATIC CN 4100 versions earlier than V5.0, but the underlying vulnerability text is Linux-kernel-specific, so applicability should be manually verified before actioning remediation.

Vendor
Siemens
Product
SIMATIC CN 4100
CVSS
HIGH 7
CISA KEV
Not listed in stored evidence
Original CVE published
2026-05-12
Original CVE updated
2026-05-14
Advisory published
2026-05-12
Advisory updated
2026-05-14

Who should care

Security and operations teams responsible for Siemens SIMATIC CN 4100 deployments, and any Linux s390 environments that use SCLP interrupt handling or related tracing code. Because the source corpus contains a product-description mismatch, asset owners should validate whether the advisory applies to their environment before scheduling remediation.

Technical summary

The issue is caused by performing the SCCB NULL check after translating a physical SCCB address into a virtual address. If the identity mapping does not begin at address zero, a NULL physical address does not translate to a zero virtual address, so the early-exit logic can be bypassed. That can lead to incorrect access to the first page of the identity mapping. The cited fix introduces handling for the NULL case before address translation.

Defensive priority

High. Validate exposure promptly and apply the vendor remediation if the Siemens advisory applies to your asset. Treat the source linkage as important but not fully resolved because of the Linux-kernel-vs-product-description inconsistency in the supplied corpus.

Recommended defensive actions

  • Confirm whether the affected asset matches Siemens SIMATIC CN 4100 versions earlier than V5.0 and whether the advisory is applicable in your environment.
  • Apply the Siemens remediation to update to V5.0 or later, per the supplied advisory reference.
  • If you operate Linux s390 systems, review kernels and build baselines that include SCLP interrupt tracing logic and prioritize patching where the issue is present.
  • Use CISA industrial control system defense-in-depth guidance and related recommended practices to reduce operational impact while remediation is planned.

Evidence notes

The supplied CISA CSAF entry states: 'In the Linux kernel, the following vulnerability has been resolved: s390/sclp: Fix SCCB present check...' and describes a NULL-check timing flaw after address translation. The same source item, however, associates the CVE with Siemens SIMATIC CN 4100 vers:intdot/<5.0. Because the advisory content and product header do not fully align, the vendor/product scope should be treated as needing manual review. CVSS vector supplied in the corpus is CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H.

Sources and references

Verified primary and authoritative sources

  • CVE-2025-39694 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2025-39694

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2025-39694 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2025-39694

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source item URL

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-134-10.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/csaf/ssa-032379.json

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/html/ssa-032379.html

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-134-10

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf

    Reference

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.