PatchSiren

PatchSiren cyber security CVE debrief

CVE-2025-38695 Siemens CVE debrief

CVE-2025-38695 is a Linux kernel null pointer dereference in the scsi: lpfc cleanup path. The advisory says a failed lpfc_sli4_read_rev() call can lead to cleanup running before sli4_hba.hdwqs are allocated, and the code may then try to access the first hardware queue's lock through a null hdwq pointer. The published fix is a null check with an early return.

Vendor
Siemens
Product
SIMATIC CN 4100
CVSS
HIGH 7
CISA KEV
Not listed in stored evidence
Original CVE published
2026-05-12
Original CVE updated
2026-05-14
Advisory published
2026-05-12
Advisory updated
2026-05-14

Who should care

Administrators, integrators, and maintenance teams responsible for the Siemens SIMATIC CN 4100 systems named in the advisory, especially any deployment running a version before V5.0. Security and operations teams should also review whether the affected Linux lpfc path exists in their broader embedded or industrial Linux estate.

Technical summary

The vulnerability is in the Linux kernel lpfc driver cleanup logic. If lpfc_sli4_read_rev() fails during lpfc_sli4_hba_setup(), the cleanup routine lpfc_sli4_vport_delete_fcp_xri_aborted() may execute before hardware queues are allocated. That creates a path where taking abts_io_buf_list_lock for the first queue can dereference phba->sli4_hba.hdwq while it is still null. The remediation is to check phba->sli4_hba.hdwq and return early when initialization has already failed.

Defensive priority

High priority for affected deployments: the advisory rates the issue HIGH and assigns high impact to confidentiality, integrity, and availability in the provided CVSS vector, with vendor remediation directing upgrades to V5.0 or later.

Recommended defensive actions

  • Verify whether your Siemens SIMATIC CN 4100 deployment is in scope of the advisory and whether it is running a version earlier than V5.0.
  • Apply the vendor remediation and upgrade to V5.0 or later as directed by Siemens.
  • Use a maintenance window and validate the update in your operational environment before broad rollout.
  • Review CISA and Siemens advisory updates for any revisions to affected versions or remediation guidance.
  • Follow CISA industrial control system defensive guidance and defense-in-depth practices while remediation is planned.

Evidence notes

The source advisory text explicitly states that a failure in lpfc_sli4_read_rev() during lpfc_sli4_hba_setup() can leave sli4_hba.hdwqs unallocated, and that cleanup may then dereference a null hdwq pointer when taking abts_io_buf_list_lock. The source also provides the CVSS vector CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H, references CWE-476, and records a Siemens remediation to update to V5.0 or later. CISA lists the advisory publication date as 2026-05-12 and a republication on 2026-05-14.

Sources and references

Verified primary and authoritative sources

  • CVE-2025-38695 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2025-38695

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2025-38695 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2025-38695

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source item URL

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-134-10.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/csaf/ssa-032379.json

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/html/ssa-032379.html

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-134-10

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf

    Reference

Methodology and review provenance