PatchSiren cyber security CVE debrief
CVE-2025-38677 Siemens CVE debrief
CVE-2025-38677 describes an out-of-boundary access in the Linux kernel F2FS path, specifically during dnode handling in f2fs_get_dnode_of_data(). The advisory text says a corrupted image can cause a dnode to be parsed as an inode node, leading to an invalid block-address calculation and an out-of-bounds access. The fix adds a sanity check for node IDs of direct nodes during dnode lookup. The source advisory was published on 2026-05-12 and republished by CISA on 2026-05-14.
- Vendor
- Siemens
- Product
- SIMATIC CN 4100
- CVSS
- MEDIUM 5.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-05-12
- Original CVE updated
- 2026-05-14
- Advisory published
- 2026-05-12
- Advisory updated
- 2026-05-14
Who should care
Operators of systems that rely on the affected Siemens advisory and teams maintaining Linux-based embedded or industrial devices with F2FS support should review this CVE. This is especially relevant where storage corruption, untrusted media, or filesystem integrity issues could be introduced into an operational device.
Technical summary
The provided source says the flaw is in f2fs_get_dnode_of_data() in the Linux kernel. When a corrupted image causes a dnode to share the same node ID as its inode, the code can misinterpret the node type. That leads to a bad address calculation for a direct node entry and an out-of-bounds page access. The stated remediation is to add sanity checking for the node ID of all direct nodes during f2fs_get_dnode_of_data(). The advisory assigns CVSS 3.1 AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H, score 5.5 (Medium).
Defensive priority
Moderate. The issue is locally triggered and rated Medium, but it can still matter in embedded and industrial environments where filesystem corruption or maliciously crafted media may be introduced into a device.
Recommended defensive actions
- Apply the vendor remediation listed in the source advisory: update to V5.0 or later where applicable.
- Review whether any affected devices or images use F2FS and could process corrupted or untrusted storage content.
- Prioritize patching systems that accept removable media, imported images, or other externally supplied filesystem data.
- Validate backup and recovery procedures for devices that depend on the affected storage stack.
- Monitor vendor and CISA advisory updates for scope clarifications, since the source mapping to the Siemens product is marked low confidence and needs review.
Evidence notes
Source text explicitly states: “f2fs: fix to avoid out-of-boundary access in dnode page.” It further explains that a corrupted image can cause a dnode to be treated as an inode node, producing an out-of-bounds access during f2fs_get_dnode_of_data(). The advisory source is CISA CSAF ICSA-26-134-10, republished from Siemens ProductCERT SSA-032379. The provided timing fields show publishedAt 2026-05-12 and modifiedAt 2026-05-14; those dates are used here as the CVE disclosure timeline. The source also lists CVSS 3.1 vector AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H, score 5.5.
Sources and references
Verified primary and authoritative sources
-
CVE-2025-38677 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2025-38677
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2025-38677 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2025-38677
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-134-10.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-032379.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-032379.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-134-10
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.