PatchSiren cyber security CVE debrief
CVE-2024-7264 Siemens CVE debrief
CVE-2024-7264 is a low-severity memory-safety issue in libcurl’s ASN.1 Generalized Time parsing logic as shipped in Siemens SINEC OS. Siemens and CISA describe a path where syntactically incorrect ASN.1 time data can cause the parser to treat a time-fraction length as -1, leading to strlen() being called on a heap buffer that is not intentionally NUL-terminated. The most likely outcome is a crash; under CURLINFO_CERTINFO, the flaw can also expose heap contents to the application.
- Vendor
- Siemens
- Product
- RUGGEDCOM RST2428P (6GK6242-6PA00)
- CVSS
- LOW 3.7
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-08-12
- Original CVE updated
- 2026-02-25
- Advisory published
- 2025-08-12
- Advisory updated
- 2026-02-25
Who should care
OT operators, Siemens product owners, firmware managers, and security teams responsible for Siemens SINEC OS-based devices should review this advisory, especially where affected network infrastructure is deployed and maintained in production environments.
Technical summary
The issue is in libcurl’s GTime2str() ASN.1 Generalized Time parsing path. When malformed input reaches the parser, an incorrect length value can cause strlen() to read beyond the intended string boundary in a heap buffer that is not NUL-terminated. CISA’s republication and Siemens’ advisory indicate that the practical impact is mainly denial of service via crash, with limited information disclosure possible when CURLINFO_CERTINFO is enabled.
Defensive priority
Medium for exposed or operationally critical Siemens deployments; otherwise schedule remediation through normal maintenance. The CVSS score is low (3.7), but the failure can crash affected software and may disclose heap contents in some application configurations.
Recommended defensive actions
- Update affected Siemens products to V3.3 or later, per Siemens remediation guidance.
- Inventory Siemens devices and confirm whether they use the affected SINEC OS firmware branches listed in the advisory.
- Prioritize remediation for systems that are operationally critical, remotely managed, or where certificate information collection is enabled.
- Validate firmware compatibility and schedule updates during approved maintenance windows.
- Monitor affected devices and management applications for unexpected crashes or abnormal certificate-handling behavior until patched.
- Use Siemens and CISA advisory references to confirm the exact affected product IDs before changing production systems.
Evidence notes
CISA’s CSAF republication for ICSA-26-043-06 was published on 2026-01-28 and updated on 2026-02-25; the revision history states that later updates clarified the affected-product scope and that only SINEC OS firmware is impacted. Siemens’ remediation guidance in the supplied references directs customers to update to V3.3 or later. The public description ties the vulnerability to libcurl’s ASN.1 parser and notes possible crash behavior plus heap-content exposure when CURLINFO_CERTINFO is used.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-7264 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-7264
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-7264 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-7264
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-043-06.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-089022.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-089022.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-043-06
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance