PatchSiren cyber security CVE debrief
CVE-2024-57256 Siemens CVE debrief
CVE-2024-57256 describes an integer overflow in Das U-Boot’s ext4fs_read_symlink path when processing a crafted ext4 filesystem. According to the advisory, an inode size of 0xffffffff can cause a zalloc size calculation to wrap, resulting in a zero-byte allocation and a memory overwrite. Siemens lists affected RUGGEDCOM ROX devices and provides a fix in V2.17.1 or later.
- Vendor
- Siemens
- Product
- RUGGEDCOM ROX MX5000
- CVSS
- HIGH 7.1
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-05-12
- Original CVE updated
- 2026-05-14
- Advisory published
- 2026-05-12
- Advisory updated
- 2026-05-14
Who should care
Operators and maintainers of Siemens RUGGEDCOM ROX devices, especially MX5000 and the RX-series models listed in the advisory, should review this immediately. Security teams responsible for embedded Linux boot components or field-updatable industrial devices should also assess exposure.
Technical summary
The issue is an integer overflow in ext4fs_read_symlink in Das U-Boot before 2025.01-rc1. The advisory states that a crafted ext4 filesystem with an inode size of 0xffffffff can overflow the allocation calculation used for zalloc, so the resulting allocation may be zero and subsequent writes can overwrite memory. The CVSS vector provided by the source is CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H, indicating physical access and high attack complexity.
Defensive priority
High. The vulnerability is rated CVSS 7.1 and affects industrial equipment boot/media handling code, so remediation should be prioritized for any deployed or maintenance-path-accessible affected device. Because the source vector indicates physical access and high complexity, focus first on systems where removable media or local maintenance workflows are realistic.
Recommended defensive actions
- Update affected Siemens RUGGEDCOM ROX products to V2.17.1 or later, per the vendor remediation.
- Verify which ROX models and firmware builds are in use against the advisory’s affected-product list.
- Restrict and monitor physical access, removable media use, and maintenance workflows around affected devices until patched.
- Use Siemens and CISA advisory references to confirm whether any device-specific compensating controls are recommended.
- Track the upstream U-Boot fix context for embedded components that may inherit the same code path.
- Document patch status and exception handling for any devices that cannot be updated immediately.
Evidence notes
Based only on the cited Siemens ProductCERT advisory republished by CISA (ICSA-26-134-16) and the associated CVE record. The source description states: an integer overflow in ext4fs_read_symlink in Das U-Boot before 2025.01-rc1 occurs for zalloc when adding one to an le32 variable via a crafted ext4 filesystem with an inode size of 0xffffffff, resulting in a malloc of zero and resultant memory overwrite. CISA’s source metadata shows publication on 2026-05-12 and republication on 2026-05-14, and the source remediation is V2.17.1 or later.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-57256 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-57256
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-57256 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-57256
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-134-16.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-577017.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-577017.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-134-16
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.