CVE-2024-56836 affects Siemens RUGGEDCOM ROX II family devices and is described in the official CISA CSAF advisory and Siemens ProductCERT notice. The issue involves injection of additional configuration parameters during Dynamic DNS configuration; under certain circumstances, an attacker could leverage it to spawn a reverse shell and gain root access. Siemens’ documented remediation is to update to V2.17.0 or later.
- Vendor
- Siemens
- Product
- RUGGEDCOM ROX II family
- CVSS
- HIGH 7.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-12-09
- Original CVE updated
- 2025-12-09
- Advisory published
- 2025-12-09
- Advisory updated
- 2025-12-09
Who should care
Operators, integrators, and defenders responsible for Siemens RUGGEDCOM ROX II family deployments should treat this as a high-priority issue, especially where Dynamic DNS configuration is enabled or remotely accessible.
Technical summary
The advisory describes a configuration-injection weakness in the Dynamic DNS feature path. The supplied CVSS vector (CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C) indicates network attackability with some prerequisite complexity and limited privileges, but potentially severe confidentiality, integrity, and availability impact if abused. The official description states that exploitation can, under certain circumstances, lead to reverse shell execution and root access on the affected system.
Defensive priority
High. The combination of remote attack potential, privilege impact, and root compromise risk warrants prompt patching and access review, even though the CVSS attack complexity is high.
Recommended defensive actions
- Update Siemens RUGGEDCOM ROX II family devices to V2.17.0 or later, as recommended in the vendor remediation.
- Review whether Dynamic DNS configuration is needed on deployed systems and disable or restrict it where possible.
- Limit administrative access to trusted management networks and accounts, and verify that least-privilege principles are enforced.
- Audit device configuration changes and look for unauthorized or unexpected Dynamic DNS parameter additions.
- Apply CISA-recommended ICS defensive practices and Siemens guidance for industrial control system hardening.
Evidence notes
This debrief is based only on the supplied official sources: the CISA CSAF advisory metadata and references, plus the Siemens ProductCERT remediation link cited in the corpus. The vulnerability description, affected vendor/product family, and remediation to V2.17.0 or later come from that corpus. CVSS details are taken from the supplied CSAF metadata. No KEV listing is present in the supplied data.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-56836 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-56836
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-56836 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-56836
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-015-11.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-912274.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-912274.html
Reference
-
Source reference
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-26-015-11.json
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-11
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.