PatchSiren cyber security CVE debrief
CVE-2024-56182 Siemens CVE debrief
CVE-2024-56182 describes a weakness in how EFI variables are protected on a broad set of Siemens SIMATIC Field PG and IPC devices. A local, authenticated attacker with high privileges could interact with the flash controller and disable the BIOS password without authorization. NVD rates the issue 8.4 (HIGH).
- Vendor
- Siemens
- Product
- SIMATIC Field PG M5
- CVSS
- HIGH 8.2
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-03-11
- Original CVE updated
- 2026-09-15
- Advisory published
- 2025-03-11
- Advisory updated
- 2026-09-15
Who should care
OT and industrial IT teams running Siemens SIMATIC Field PG or SIMATIC IPC systems, especially administrators who rely on BIOS passwords or manage device firmware and physical access controls.
Technical summary
The supplied description says affected devices have insufficient protection for EFI variables stored on the device. The CVSS v4.0 vector (AV:L/PR:H/UI:N) indicates a local attack requiring high privileges. Per the record, an authenticated attacker may be able to directly communicate with the flash controller and disable the BIOS password. NVD maps the weakness to CWE-693 and lists the vulnerability status as Deferred.
Defensive priority
High. The issue affects many Siemens SIMATIC industrial PC and Field PG platforms and can undermine BIOS password protections that organizations may rely on for device hardening and physical security.
Recommended defensive actions
- Review Siemens advisory SSA-216014 and apply the vendor-recommended firmware/BIOS update for each affected model.
- Confirm every deployed SIMATIC Field PG/IPC variant is on a remediated version or later, especially where the description lists all versions as affected.
- Restrict local administrative access and physical access to affected systems until remediation is complete.
- Audit whether BIOS password controls are used as a security boundary and add compensating controls where needed.
- Track remediation status across engineering workstations and embedded IPC fleets, including spare and field-deployed units.
Evidence notes
The vulnerability description and product scope come from the supplied CVE text and the Siemens advisory reference linked by NVD (SSA-216014). NVD metadata shows CVSS v4.0 8.4 HIGH, vector AV:L/PR:H/UI:N, CWE-693, and vulnStatus 'Deferred' as of the latest supplied modification date (2026-05-12). No exploit details or unsupported remediation versions are included beyond the supplied advisory reference.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-56182 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-56182
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-56182 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-56182
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-216014.html
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.