CVE-2024-5594 Siemens CVE debrief
CVE-2024-5594 affects Siemens SINEMA Remote Connect Server and was publicly disclosed on 2025-03-11 in Siemens/CISA advisories. The issue is in control-channel message handling: messages containing nonprintable characters should be refused, but the advisory notes that a malicious OpenVPN peer could otherwise cause garbage to be written to the OpenVPN log or trigger high CPU load. Siemens provides a fixed release recommendation: update to V3.2 SP3 or later.
- Vendor
- Siemens
- Product
- SINEMA Remote Connect Server
- CVSS
- MEDIUM 5.4
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-03-11
- Original CVE updated
- 2025-03-11
- Advisory published
- 2025-03-11
- Advisory updated
- 2025-03-11
Who should care
Organizations running Siemens SINEMA Remote Connect Server, especially teams responsible for remote access, OT network monitoring, and patching of externally reachable VPN/control-channel components. Operators should care even though the severity is medium, because the issue can impact logging integrity and availability.
Technical summary
The advisory describes a validation weakness in control-channel message handling. Nonprintable characters are supposed to be rejected, but malformed input from a malicious OpenVPN peer can be accepted far enough to affect logging and CPU usage. The published CVSS vector is AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L, indicating network reachability, low privileges, no user interaction, and limited integrity/availability impact.
Defensive priority
Medium priority. Remediate as part of routine OT remote-access hardening, and elevate priority if the affected server is internet-reachable, broadly exposed to partner connectivity, or operationally sensitive to logging/CPU degradation.
Recommended defensive actions
- Upgrade Siemens SINEMA Remote Connect Server to V3.2 SP3 or later.
- Review exposure of the remote-access/control-channel service and restrict access to only required peers.
- Monitor for abnormal log content and unexpected CPU spikes on affected systems until remediation is complete.
- Track Siemens and CISA advisories for any follow-up guidance or product-specific mitigations.
Evidence notes
Primary evidence comes from the CISA CSAF advisory ICSA-25-072-02 and Siemens' linked security advisory resources. The supplied description explicitly states: 'control channel: refuse control channel messages with nonprintable characters in them' and notes that a malicious OpenVPN peer can send garbage to the OpenVPN log or cause high CPU load. The remediated version is listed by Siemens as V3.2 SP3 or later. The provided CVSS vector is CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L/E:U/RL:O/RC:C.
Official resources
-
CVE-2024-5594 CVE record
CVE.org
-
CVE-2024-5594 NVD detail
NVD
-
Source item URL
cisa_csaf
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
Publicly disclosed by Siemens and CISA on 2025-03-11; no KEV listing was provided in the supplied corpus.