PatchSiren

PatchSiren cyber security CVE debrief

CVE-2024-53242 Siemens CVE debrief

This CVE debrief is based on the supplied source corpus. The CVE record was published on 2024-10-08T00:00:00.000Z and has not been modified since then. The NVD entry is currently HIGH. CVE-2024-53242 is a high-severity vulnerability in Siemens Tecnomatix Plant Simulation V2302 and V2404 applications, potentially allowing code execution. Defenders should prioritize patching and verify affected versions. The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.

Vendor
Siemens
Product
Tecnomatix Plant Simulation V2302
CVSS
HIGH 7.8
CISA KEV
Not listed in stored evidence
Original CVE published
2024-10-08
Original CVE updated
2025-05-06
Advisory published
2024-10-08
Advisory updated
2025-05-06

Who should care

Defenders responsible for Siemens Tecnomatix Plant Simulation V2302 and V2404 applications should assess exposure and prioritize patching due to the high CVSS score and potential for code execution.

Why it matters

CVE-2024-53242 is a high-severity vulnerability in Siemens Tecnomatix Plant Simulation V2302 and V2404 applications, potentially allowing code execution. Defenders should prioritize patching and verify affected versions.

  • Potential code execution in the context of the current process
  • Requires patching or mitigation to prevent exploitation
  • Defenders should verify affected versions and apply updates
  • Inventory checks and monitoring are necessary to detect potential exposure

Technical summary

The affected Siemens Tecnomatix Plant Simulation V2302 and V2404 applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. The vulnerability has a high CVSS score of 7.8 and requires patching or mitigation to prevent exploitation. Defenders should verify affected versions and apply updates to prevent potential code execution in the context of the current process. The vulnerability was reported by ZDI-CAN-25206 and has a HIGH severity rating.

Defensive priority

Defenders should prioritize patching affected Tecnomatix Plant Simulation V2302 and V2404 applications due to a high CVSS score of 7.8.

Recommended defensive actions

  • Patch affected Tecnomatix Plant Simulation V2302 and V2404 applications
  • Do not open untrusted WRL files in affected applications
  • Update to V2302.0016 or later version for V2302
  • Update to V2404.0005 or later version for V2404
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up

Evidence notes

The source corpus provides details on the vulnerability, including an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files, which could allow an attacker to execute code in the context of the current process.

Sources and references

Verified primary and authoritative sources

  • CVE-2024-53242 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2024-53242

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2024-53242 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2024-53242

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • CVE-2024-53242

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-284-13.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/csaf/ssa-583523.json

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/html/ssa-583523.html

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-13

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf

    Supplemental source

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.