PatchSiren cyber security CVE debrief
CVE-2024-53181 Siemens CVE debrief
A vulnerability in the Linux kernel's User-Mode Linux (UML) vector driver could allow a local attacker to cause a denial of service condition. The issue stems from improper handling of driver data during release operations, where drvdata is not available when expected. This affects Siemens industrial networking products running SINEC OS, specifically the RUGGEDCOM RST2428P and SCALANCE switch families. The vulnerability requires local access and low privileges to exploit, with no impact to confidentiality or integrity, but high availability impact. Siemens has released updates to address this issue.
- Vendor
- Siemens
- Product
- RUGGEDCOM RST2428P (6GK6242-6PA00)
- CVSS
- MEDIUM 5.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-08-12
- Original CVE updated
- 2026-02-25
- Advisory published
- 2025-08-12
- Advisory updated
- 2026-02-25
Who should care
Organizations operating Siemens RUGGEDCOM RST2428P switches or SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 and XCM-/XRM-/XCH-/XRH-300 family switches in industrial environments. Critical infrastructure operators, manufacturing facilities, and utility providers using these devices for network infrastructure should prioritize patching.
Technical summary
The vulnerability exists in the User-Mode Linux (UML) vector driver where driver data (drvdata) is not properly available during release operations. This can lead to a NULL pointer dereference or use-after-free condition, resulting in system crash or denial of service. The CVSS 3.1 base score of 5.5 reflects local attack vector, low attack complexity, low privileges required, and high availability impact with no confidentiality or integrity effects. Affected Siemens products incorporate this vulnerable kernel component in their SINEC OS firmware.
Defensive priority
medium
Recommended defensive actions
- Apply vendor-provided updates to V3.2 or later for affected RUGGEDCOM and SCALANCE products per Siemens ProductCERT guidance
- For SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family, consult Siemens support documentation for specific configuration guidance
- Implement defense-in-depth strategies for industrial control systems per CISA recommended practices
- Restrict local access to affected systems to authorized personnel only
- Monitor for anomalous system behavior or unexpected reboots on affected devices
Evidence notes
CVE published 2025-08-12 per CISA CSAF advisory ICSA-25-226-07. Modified 2026-02-25. Advisory last updated to reflect Siemens ProductCERT SSA-355557 republication. CVSS 3.1 vector: AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H. CWE-20 (Improper Input Validation) identified.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-53181 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-53181
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-53181 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-53181
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-226-07.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-355557.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-355557.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-07
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.