PatchSiren

PatchSiren cyber security CVE debrief

CVE-2024-46890 Siemens CVE debrief

The CVE-2024-46890 vulnerability affects Siemens SINEC INS, allowing an authenticated remote attacker with high privileges to execute arbitrary code on the underlying OS due to improper input validation in specific web API endpoints. Siemens has released an update to V1.0 SP2 Update 3 or later version to address this issue. The vulnerability's impact includes potential code execution on the underlying OS, elevation of privileges for attackers, and compromise of affected systems. Defenders should assess exposure and prioritize updates to prevent potential compromise.

Vendor
Siemens
Product
SINEC INS
CVSS
CRITICAL 9.1
CISA KEV
Not listed in stored evidence
Original CVE published
2024-11-12
Original CVE updated
2024-11-12
Advisory published
2024-11-12
Advisory updated
2024-11-12

Who should care

Defenders responsible for Siemens SINEC INS systems should assess exposure and prioritize updates to prevent potential code execution. This includes operators, platform administrators, vulnerability management teams, and security teams who need to review and implement mitigations. Affected systems may be part of industrial control processes, and defenders should consider the potential operational impacts of a compromise.

Why it matters

CVE-2024-46890 affects Siemens SINEC INS, allowing code execution via improper input validation. Defenders should prioritize updates and monitoring to prevent potential compromise.

  • Potential code execution on underlying OS
  • Elevation of privileges for attackers
  • Compromise of affected systems
  • Disruption of industrial control processes

Technical summary

The affected application does not properly validate input sent to specific endpoints of its web API, allowing an authenticated remote attacker with high privileges on the application to execute arbitrary code on the underlying OS. This vulnerability affects Siemens SINEC INS and defenders should prioritize updating affected systems to prevent potential code execution. The vulnerability's technical details include improper input validation and potential code execution on the underlying OS. Siemens has released an update to address this issue.

Defensive priority

Defenders should prioritize updating affected systems to prevent potential code execution.

Recommended defensive actions

  • Update to V1.0 SP2 Update 3 or later version
  • Verify input validation for web API endpoints
  • Monitor for suspicious activity
  • Review compensating controls for exposed systems
  • Check relevant monitoring, detection, and logs for exposed assets
  • Track exceptions, retest remediated assets
  • Confirm whether affected product deployments exist in managed environments

Evidence notes

The CVE record and CISA CSAF advisory provide details on the vulnerability and affected product. The affected application does not properly validate input sent to specific endpoints of its web API. This could allow an authenticated remote attacker with high privileges on the application to execute arbitrary code on the underlying OS. Evidence is limited to public sources and may not reflect the full scope of affected systems or potential impacts.

Sources and references

Verified primary and authoritative sources

  • CVE-2024-46890 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2024-46890

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2024-46890 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2024-46890

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • CVE-2024-46890

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-319-08.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/csaf/ssa-915275.json

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/html/ssa-915275.html

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-319-08

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf

    Supplemental source

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.